Technical Data

Technical Data

 

 

 

 

 

XP Proportioners

 

 

 

U.S.

Metric

Maximum Fluid Working Pressure

See Models section beginning

on page 11.

Maximum Air/Hydraulic Oil Working Pressure

See Models section beginning on page 11.

Combined Fluid Output (cc/cycle)

See Models section beginning on page 11.

Pressure Ratio

See Models section beginning on page 11.

Fluid Flow at 40 cpm

See Models section beginning on page 11.

Hydraulic Fluid Consumption (XP-h models only)

0.2 gallons per cycle

0.76 liters per cycle

 

 

 

Air inlet size

3/4 npsm(f)

 

Maximum air pressure supply to the system

175 psi

12 bar, 1 MPa

Fluid pump inlets without hoppers

1-1/4 in. npsm(m)

 

 

 

 

Fluid gauge manifold outlets

1/2 in. npt(f)

 

Fluid mix manifold inlets

1/2 in. npt(f) ball valves

 

Mix manifold material outlet

1/2 in. npt(f)

 

 

 

 

Maximum feed pressure from remote source

250 psi

17 bar, 1.7 MPa

Sound pressure

86 dBA at 100 psi (7 bar, 0.7

MPa)

Sound power

98 dBA at 100 psi (7 bar, 0.7 MPa)

 

 

Maximum Storage Time

5 years (To maintain original performance, replace soft

 

seals after 5 years of inactivity.)

 

 

Maximum Lifetime

Indefinite with recommended maintenance and periodic

 

rebuilds for critical parts.

 

 

 

Power Efficiency Factor (XP70)

75 cu. ft compressed air/1 gallon sprayed material at 100 psi

 

2.12 m3 compressed air/1 liter sprayed material at 7 bar

 

(0.7 MPa)

 

 

 

 

Air consumption per 1 gallon (3.78 l) of flow

 

 

XP70

75 scfm at 100 psi/gpm (2.12 m3/min at 7 bar, 0.7 MPa)

XP50

60 scfm at 100 psi/gpm (1.7 m3/min at 7 bar, 0.7 MPa)

XP35

50 scfm at 100 psi/gpm (1.42 m3/min at 7 bar, 0.7 MPa)

Filtration:

 

 

Air inlet filtration

40-micron filter/separator included

XP pump outlets

30 mesh

 

 

 

 

XTR Spray Gun

60 mesh

 

Fluid Viscosity Range:

 

 

Gravity feed with 7 gallon (26 liter) hoppers

200 to 20,000 cps (pourable)

 

 

 

Pressure feed

Any viscosity that will not require feed pressure more than

 

15% of outlet pressure

 

 

 

 

Environmental Rating (Indoor/outdoor)

 

 

Hazardous Areas

EX II 2 G c IIA T2

 

 

NOTE: XP-h pump packages (284xxx) are not Ex rated.

 

 

 

Ambient Temperature Range:

 

 

Operating

40-130°F

4-54°C

 

 

 

Storage

30-160°F

-1-71°C

Maximum Fluid Temperature

160°F

71°C

 

 

 

Wetted materials:

 

 

Housings and manifolds

Carbon steel with electroless nickel plating

Miscellaneous parts

Plated carbon steel, stainless steels, carbide, acetal, UHM-

 

WPE, nylon, PTFE solvent resistant plastics

 

 

Pump packings

Carbon filled PTFE, proprietary UHMWPE

Flush pump suction tube

Aluminum

 

 

 

 

Hoses

Nylon core

 

3A0420T