 | Technical Data | 
| Technical Data | 
 | 
 | 
| 
 | 
 | 
 | 
| XP Proportioners | 
 | 
 | 
| 
 | U.S. | Metric | 
| Maximum Fluid Working Pressure | See Models section beginning | on page 11. | 
| Maximum Air/Hydraulic Oil Working Pressure | See Models section beginning on page 11. | |
| Combined Fluid Output (cc/cycle) | See Models section beginning on page 11. | |
| Pressure Ratio | See Models section beginning on page 11. | |
| Fluid Flow at 40 cpm | See Models section beginning on page 11. | |
| Hydraulic Fluid Consumption  | 0.2 gallons per cycle | 0.76 liters per cycle | 
| 
 | 
 | 
 | 
| Air inlet size | 3/4 npsm(f) | 
 | 
| Maximum air pressure supply to the system | 175 psi | 12 bar, 1 MPa | 
| Fluid pump inlets without hoppers | 
 | |
| 
 | 
 | 
 | 
| Fluid gauge manifold outlets | 1/2 in. npt(f) | 
 | 
| Fluid mix manifold inlets | 1/2 in. npt(f) ball valves | 
 | 
| Mix manifold material outlet | 1/2 in. npt(f) | 
 | 
| 
 | 
 | 
 | 
| Maximum feed pressure from remote source | 250 psi | 17 bar, 1.7 MPa | 
| Sound pressure | 86 dBA at 100 psi (7 bar, 0.7 | MPa) | 
| Sound power | 98 dBA at 100 psi (7 bar, 0.7 MPa) | |
| 
 | 
 | |
| Maximum Storage Time | 5 years (To maintain original performance, replace soft | |
| 
 | seals after 5 years of inactivity.) | |
| 
 | 
 | |
| Maximum Lifetime | Indefinite with recommended maintenance and periodic | |
| 
 | rebuilds for critical parts. | 
 | 
| 
 | 
 | |
| Power Efficiency Factor (XP70) | 75 cu. ft compressed air/1 gallon sprayed material at 100 psi | |
| 
 | 2.12 m3 compressed air/1 liter sprayed material at 7 bar | |
| 
 | (0.7 MPa) | 
 | 
| 
 | 
 | 
 | 
| Air consumption per 1 gallon (3.78 l) of flow | 
 | 
 | 
| XP70 | 75 scfm at 100 psi/gpm (2.12 m3/min at 7 bar, 0.7 MPa) | |
| XP50 | 60 scfm at 100 psi/gpm (1.7 m3/min at 7 bar, 0.7 MPa) | |
| XP35 | 50 scfm at 100 psi/gpm (1.42 m3/min at 7 bar, 0.7 MPa) | |
| Filtration: | 
 | 
 | 
| Air inlet filtration | ||
| XP pump outlets | 30 mesh | 
 | 
| 
 | 
 | 
 | 
| XTR Spray Gun | 60 mesh | 
 | 
| Fluid Viscosity Range: | 
 | 
 | 
| Gravity feed with 7 gallon (26 liter) hoppers | 200 to 20,000 cps (pourable) | 
 | 
| 
 | 
 | |
| Pressure feed | Any viscosity that will not require feed pressure more than | |
| 
 | 15% of outlet pressure | 
 | 
| 
 | 
 | 
 | 
| Environmental Rating (Indoor/outdoor) | 
 | 
 | 
| Hazardous Areas | EX II 2 G c IIA T2 | 
 | 
| 
 | NOTE:  | |
| 
 | 
 | 
 | 
| Ambient Temperature Range: | 
 | 
 | 
| Operating | ||
| 
 | 
 | 
 | 
| Storage | ||
| Maximum Fluid Temperature | 160°F | 71°C | 
| 
 | 
 | 
 | 
| Wetted materials: | 
 | 
 | 
| Housings and manifolds | Carbon steel with electroless nickel plating | |
| Miscellaneous parts | Plated carbon steel, stainless steels, carbide, acetal, UHM- | |
| 
 | WPE, nylon, PTFE solvent resistant plastics | |
| 
 | 
 | |
| Pump packings | Carbon filled PTFE, proprietary UHMWPE | |
| Flush pump suction tube | Aluminum | 
 | 
| 
 | 
 | 
 | 
| Hoses | Nylon core | 
 | 
| 3A0420T | 57 | 