Graco 3A0420T important safety instructions System Verification

Models: 3A0420T

1 64
Download 64 pages 14.1 Kb
Page 31
Image 31

System Verification

System Verification

Graco recommends running the following tests daily.

Check for Normal Operation

Every time you start spraying:

Watch the fluid gauges (AF). A pressure drop occurs during pump stroke changeover. It should be quick and synchronous.

Stop the pumps on the upstroke. Check that both

gauges hold pressure for at least 20 seconds. See

Pump Troubleshooting on page 34.

NOTE: If one gauge drops, the others will rise.

Stop the pumps on the downstroke. Check that all gauges hold pressure.

If using feed pumps, check that both feed pumps run during the proportioner upstroke.

Mix and Integration Tests

Use the following tests to check for proper mix and inte- gration.

Butterfly Test

At low pressure, and with the spray tip reversed, dis- pense a 1/2 in. (12.7 mm) bead of material onto foil until multiple changeovers of each pump have occurred. Fold the sheet of foil over the fluid then peel it back and look for unmixed material (appears marble-like), or color changes.

Curing Test

Spray a single continuous pattern on foil at typical pres- sure setting, flow rate, and tip size until multiple change- overs of each pump have occurred. Trigger and de-trigger at typical intervals for the application. Do not overlap or cross over your spray pattern.

Check curing at various time intervals, listed on the material data sheet. For example, check for dry to touch by running your finger along the test pattern’s entire length at the time listed on the data sheet.

NOTE: Spots that take longer to cure indicate insuf- ficient pump loading, leakage, or lead/lag errors at a remote mix manifold.

Appearance Test

Spray material onto foil. Look for variations in color, gloss, or texture that may indicate improperly catalyzed material.

Monitor Fluid Supply

NOTICE

To prevent pumping air into the system, which causes incorrect proportioning, never allow the feed pump or solvent pump containers to run dry.

An empty pump will quickly accelerate to a high speed, and may damage itself and the other displacement pump because it causes a pressure rise in the other pump. If a supply container runs dry, stop the pump immediately, refill the container, and prime the system. Be sure to eliminate all air from the system.

Check Pot Life

Check the fluid manufacturer's instructions for fluid pot life at your fluid temperature. Flush mixed fluid out of the mix manifold, hose, and gun before pot life time expires, or before a rise in viscosity affects the spray pattern.

Ratio Check

Check the ratio at the mix manifold after any changes to the proportioning system. Use Ratio Check Kit 24F375 to check the ratio at the mix manifold. See manual ratio check kit manual for instructions and parts.

NOTE: To prevent an inaccurate ratio check when feed pumps are used in your system, the feed pres- sure cannot be more than a maximum of 25% of the proportioner outlet pressure. High feed pressure can float the proportioner pump check balls, result- ing in an inaccurate ratio check. There must be back pressure on both sides of the mix manifold when checking the ratio.

3A0420T

31