13.When the water level reaches the bung seal, rotate the handle to release the bung pin (this will cause the bung to pop up against the seal and close the bung).

Operation

15.Wait for pot pressure to increase. NOTE: It can take up to several minutes for the pot to pressurize.

14. Turn the selector valve to FILL.

NOTE: The water pump should begin cycling. If not, open the pot pressure regulator enough to cause the pump to run at 60 cpm.

NOTE: The auto vent/purge valve will allow all of the air trapped in the top of the pot to vent. When air stops venting, the pot pressure gauge will start to register pressure.

ti24824a

NOTE: The bung cannot be pushed down unless all of the pressure in the pot is released by opening the dump valve.

16.Set the pot pressure 30 psi (2.0 Bar, 0.2 MPa) higher than the intended blast pressure. Quickly open and close the dump valve after the pump stalls. Relieve pot pressure to 40 psi (2.7 Bar, 0.27 MPa) before closing the dump valve. Repeat until pot pressure is consistent.

17.Turn the selector valve to WASH.

18.Set the blast air pressure 30 psi (2.0 Bar, 0.2 MPa) lower than the pot pressure while blasting.

NOTE: In order to adjust the blast pressure, the blast control must be engaged. For the initial setting, leave the abrasive ball valve closed.

NOTE: Engage and release the blast control handle each time the blast regulator is adjusted.

19. Turn the selector valve to BLAST.

334667B

13

Page 13
Image 13
Graco EQ300C manual Ti24824a