Operation
20.Opentheabrasiveballvalve.
NOTE: NOTE:
NOTE:Makesurethepotpressurereturnstothe
initialsetting(itwillnotreturntotheinitialsetting
ifthemeteringvalveisclosed).
21.Engagetheblastcontrolswitchandbegin
blasting.
NOTE: NOTE:
NOTE:Youmayhavetowait1–2minutesforthe
abrasivematerialtoreachthenozzle.
NOTE: NOTE:
NOTE:Potpressureandblastpressureshould
equalizeduringblasting.Onlysetpotpressure
withtheabrasiveballvalveclosed.Neveradjust
potpressurewhileblasting.
22.Slowlyadjusttheabrasivemetervalvewhilethe
abrasiveisblastingfromthenozzle.Typical
adjustmentrangesfrom1/8to1/4turnopen.
NOTE: NOTE:
NOTE:TheDataTrakcanbeusedtoassistin
settingthepumpcyclerate.Optimalabrasive
mediaconsumptiontypicallyoccurswiththe
cycleratesetat7–10cyclesperminute.
8800000
83000
9
NOTE: NOTE:
NOTE:Useapieceoftestmaterialsimilarto
whatyouwillbeblasting.
NOTE: NOTE:
NOTE:Alwaysstartasgentlyaspossibleand
thenincreasetheblastforceasnecessaryto
cleanwithoutdoinganydamagetothesubstrate.
Whenproperlyset,thepumpshouldcycle7-10
timesperminute.Highproductionrateusers
mayneedtoincreasecyclerateabove10cycles
perminute.
NOTE: NOTE:
NOTE:Closetheabrasiveballvalvewhenever
youstopblastingformorethan2-3minutes.
Thiswillhelptoextendtheservicelifeofthe
diaphragmvalve.
14
334667B