OEM System Guidelines

OEM System Guidelines

 

U.S.

Metric

System Weight (Dry)

450 lb

204 kg

System Weight (Wet)

1600 lb

726 kg

Water Tank Size (must be water

100 gallon (recommended)

378 liter (recommended)

compatible)

 

 

Pump Inlet Fitting

Dixon 6EM6-B quick disconnect interchange included

 

(3/4" NPT also on pump)

Minimum ID

3/4 in.

1.9 cm

Maximum Recommended Pump Inlet

5 ft

4.5 m

Hose Length

 

 

Maximum recommended rise from water

16 in.

41 cm

tank outlet to pump inlet

 

 

Available Graco Inlet hoses (w/ quick

 

 

disconnect interchanges)

 

 

17C032

19 in. length

48 cm

EQ1848

36 in. length

91 cm

Available Graco water tank shutoff valve

EQ5131

EQ5131

assembly (3/4" NPT male to 6EM6-B

 

 

quick disconnect)

 

 

Compressor Size and Hose Length

 

Minimum ID

 

 

U.S.

 

Metric

185-600 cfm compressor and less than

1.5 in.

 

38

mm

100' hose length

 

 

 

 

More than 600 cfm compressor or

2 in.

 

51

mm

greater than 100' hose length

 

 

 

 

See Vapor Abrasive Blast Systems and Accessories, page 40 for Graco recommended blast hoses and nozzles.

See Dimensions, page 44.

334667B