Graco 1095, Mark VII, Mark IV, Mark X, 795, 695, 1595 important safety instructions Setup

Models: Mark V 795 Mark X

1 44
Download 44 pages 42.16 Kb
Page 14
Image 14
Setup

Setup

Setup

1.All sprayers except ProContractor: Connect Graco airless hose to sprayer. Tighten securely.

ti22875a

If using the optional hopper, remove the nipple fit- ting from the filter. Install 45° elbow (from parts box) into filter and install nipple fitting into elbow. Then connect the hose to the nipple.

ti18631a

NOTE: Make sure nipple fitting is angled away from hopper so the hose can be easily installed.

2.Connect whip hose (if applicable) and gun to other end of hose. Tighten securely.

ti18195a

3. Engage trigger lock.

ti18199a

4. Remove tip guard.

ti2769a

5. Check inlet strainer for clogs and debris.

ti17608b

6.Fill throat packing nut with Graco TSL to prevent premature packing wear. Do this each time you spray.

ti18421b

7. Turn power OFF.

ti22950a

8.Plug power supply cord into a properly grounded electrical outlet.

9.Turn prime valve down to DRAIN position.

ti14842a

10.Place pump in grounded metal pail partially filled with flushing fluid. Attach ground wire to pail and to true earth ground. Perform steps 1 - 5 of Startup to flush out storage oil shipped in sprayer. Use water to flush water-base paint and mineral spirits to flush oil-base paint and storage oil.

ti18245b

14

332916C

Page 14
Image 14
Graco 1095, Mark VII, Mark IV, Mark X, 795, 695, 1595 important safety instructions Setup