Check Motor Thermal Switch: Unplug thermal

 

 

 

 

 

 

 

 

 

 

 

 

 

Troubleshooting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TYPE OF PROBLEM

WHAT TO CHECK

 

HOW TO CHECK

 

 

 

 

 

 

 

 

 

 

 

 

 

Sprayer does not run at all

Allow sprayer to cool. If sprayer

NOTE: Motor must be cooled down for the test.

 

 

 

runs when cool, correct cause of

1.

Check thermal device connector (yellow wires)

Display shows CODE 06

overheating. Keep sprayer in cooler

 

 

 

 

at control board.

 

 

 

location with good ventilation. Make

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

sure motor air intake is not blocked. 2.

Disconnect thermal device connector from control

 

 

 

If sprayer still does not run, follow

 

board socket. Make sure contacts are clean and

 

 

 

 

 

 

 

 

secure. Measure resistance of the thermal device. If

 

 

 

Step 1.

 

 

 

 

 

reading is not correct, replace motor.

 

 

 

 

 

 

 

 

 

 

Check Motor Thermal Switch: Unplug thermal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

wires. Set meter to ohms. Meter should read the

 

 

 

 

 

proper resistance for each unit (see table below).

Control board status light blinks

 

 

 

 

 

 

 

 

 

 

 

 

 

6 times repeatedly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

 

 

 

 

ti13140a

 

 

 

 

Resistance Table:

 

 

 

695/240V Mark IV

0 ohms

 

 

 

795/120V Mark IV

2k ohms

 

 

 

1095/240V Mark V

3.9k ohms

 

 

 

1595/120V Mark V/MARK VII

6.2k ohms

 

 

 

MARK X

10.0k ohms

 

 

3.

Reconnect thermal device connector to control

 

 

 

board socket. Connect power, turn sprayer ON and

 

 

 

control knob 1/2 turn clockwise. If sprayer does not

 

 

 

run, replace control board.

 

Sprayer does not run at all

Check voltage supply to the sprayer 1.

Set sprayer to OFF and disconnect power to

Display shows CODE 08

(incoming voltage too low for

 

sprayer.

 

sprayer operation)

 

 

 

 

2.

Remove other equipment that uses the same circuit.

 

 

 

 

3.

Locate a good voltage supply to avoid damage to

 

 

 

electronics.

 

Control board status light blinks

 

 

 

eight times repeatedly

 

 

 

 

 

 

 

 

Sprayer does not run at all

Check to see if control board is over 1.

Make sure motor air intake is not blocked.

 

 

 

heating.

2.

Make sure fan has not failed.

Display shows CODE 10

 

 

 

 

 

3.

Make sure control board is properly connected

 

 

 

 

 

to back plate and that conductive thermal paste

 

 

 

 

 

is used on power components.

 

 

 

 

 

 

 

 

 

4.

Replace control board.

 

 

 

 

5.

Replace motor.

 

 

 

 

 

 

 

 

 

 