Graco Mark VII, 795 Switch Tip Installation, Spray, Clearing Tip Clog, Skin Injection Hazard

Models: Mark V 795 Mark X

1 44
Download 44 pages 42.16 Kb
Page 16
Image 16
Switch Tip Installation

Switch Tip Installation

Switch Tip Installation

1.Perform Pressure Relief Procedure, page 13.

2.Use spray tip (A) to insert OneSeal(B) into guard (C).

C

B A

ti13023a

3. Insert Switch Tip.

ti13024a

4. Screw assembly onto gun. Tighten.

ti2710a

Spray

1.Spray test pattern. Increase pressure to eliminate heavy edges. Use smaller tip size if pressure adjust- ment can not eliminate heavy edges.

ti18243a

2.Hold gun perpendicular, 10-12 in. (25-30 cm) from surface. Spray back and forth. Overlap by 50%. Trigger gun after moving and release before stop- ping.

ti18242a

Clearing Tip Clog

SKIN INJECTION HAZARD

Never point gun at your hand or into a rag!

1.Release trigger, engage trigger lock. Rotate SwitchTip. Disengage trigger lock. Trigger gun to clear clog.

ti13033a

2.Engage trigger lock. Return SwitchTip to original position. Disengage trigger lock and continue spray- ing.

ti13034a

16

332916C

Page 16
Image 16
Graco Mark VII, Mark IV, 795 Switch Tip Installation, Spray, Clearing Tip Clog, Perform Pressure Relief Procedure, page