Troubleshooting
TYPE OF PROBLEM | WHAT TO CHECK | HOW TO CHECK | ||
|
|
|
|
|
Sprayer does not run at all | Excessive current protection | 1. Cycle power on and off. | ||
|
|
| enabled |
|
Display shows CODE 12 |
| |||
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Control board status light blinks 12 times repeatedly
Sprayer does not run at all | Check the connections above the | 1. | Set sprayer to OFF and disconnect power to | ||
|
|
| motor |
| sprayer. |
Display shows CODE 15 |
| ||||
|
|
| |||
|
|
|
| 2. | Remove motor shroud. |
|
|
|
| 3. | Disconnect motor control and inspect for damage at |
|
|
|
| ||
|
|
|
|
| connectors. |
|
|
|
| 4. | Reconnect motor control. |
|
|
|
| 5. | Turn power on. If code continues, replace motor. |
|
|
|
| ||
|
|
|
| ||
|
|
|
|
|
|
Control board status light blinks |
|
|
| ||
15 times repeatedly |
|
|
| ||
|
|
|
|
|
|
Sprayer does not run at all | Check the connections. Control | 1. | Turn power OFF. | ||
|
|
| is not receiving a motor position | 2. | Disconnect motor position sensor and inspect for |
Digital display shows CODE 16 | |||||
|
|
| sensor signal |
| damage at connectors. |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Control board status light blinks |
| ti18685a |
| ||
16 times repeatedly | 3. Reconnect sensor. | |
|
4. Turn power ON. If code continues, replace motor.
Sprayer does not run at all | Check voltage supply to the sprayer | 1. | Set sprayer to OFF and disconnect power to | ||
|
|
| (sprayer plugged into wrong |
| sprayer. |
Display shows CODE 17 |
| ||||
voltage) |
|
| |||
|
|
| 2. | Locate a good voltage supply to avoid damage to | |
|
|
|
| ||
|
|
|
|
| electronics. |
|
|
|
|
|
|
Control board status light blinks 17 times repeatedly
32 | 332916C |