Maintenance

Clean Orifice

1.Follow Pressure Relief Procedure on page 22.

2.Use 5/16 in. nut driver (supplied) to remove orifices (C). See FIG. 4 on page 16.

NOTICE

To prevent cross-contamination of the orifices do not interchange A component and B component parts. The A component orifice is marked with an A.

NOTE: The cap is held in place with reverse threads.

3.Remove cap (26) from orifice (25). See Parts on page 42.

4.Remove needle (60) from orifice. Thoroughly inspect all o-rings and replace if necessary.

5.If necessary, use drill bit that is the same size as the orifice to drill out the orifice. Orifice size is marked on the orifice.

6.Use Fusion grease to liberally lubricate all o-rings.

7.Reassemble in reverse order. Torque orifice body into orifice cap to 60-70 in-lb (6.78-7.91 N•m). Torque orifices into fluid housing to 20-30 in-lb (2.26-3.39 N•m).