18.Use hex nut driver to install fluid manifold (AD). Torque fluid manifold bolt to 20-30 in-lb

(2.26-3.39 N•m). Connect air quick coupler (AC).

AD

AC

Repair

Purge Rod

1.Flush Gun, page 25.

2.Follow Pressure Relief Procedure, page 22.

3.Disconnect air quick coupler (AC). Use hex nut driver to remove fluid manifold (AD).

TI14484a

19. Connect signal cable.

AD

AC

TI14463a

4. Disconnect signal cable.

5. Remove Front End, see page 33. Inspect purge rod for wear or damage. Replace if necessary.

6. Use 3/4 in. wrench to loosen front tip. Coat purge rod with TSL then replace purge rod.

7. Attach Front End, see page 35.

8. Attach air quick coupler to fully extend purge rod. Tighten front tip to 60-70 in-lb (6.78-7.91 N•m)

9. Install fluid manifold. Torque fluid manifold bolt to 20-30 in-lb (2.26-3.39 N•m).

10. Connect signal cable.

313872B

37

Page 37
Image 37
Graco Inc 257999, 313872B, 24C934, 24C932, 24C933, TI14450a important safety instructions Purge Rod