Remove Front End

NOTICE

Proper attachment of front end is critical. Do not operate gun if front end is loose or not snug against body. Improper attachment can cause slow leaks.

1.Perform Pressure Relief Procedure, page 22.

2.Flush Gun, see page 25.

3.Perform Bleed Throat Seal Liquid Cartridge pro- cedure on page 24 to bleed all fluid from cartridge or replace with empty cartridge. TSL will spill if any fluid remains in cartridge after this step.

4.Disconnect air quick coupler (AC). Use hex nut driver to remove fluid manifold (AD).

AD

AC

TI14463a

5.Disconnect signal cable.

6.Rotate fluid housing (AK) 45 degrees counterclock- wise to disengage fluid housing slots.

AK

ti14479a

Repair

7.Pull fluid housing away from gun body to remove. If fluid housing cannot be removed perform the follow- ing steps.

a.Attach air quick coupler.

b.Pull and release the trigger or press and release the red button on the solenoid valve.

c.Remove fluid housing.

d.Disconnect air quick coupler.

8.Disengage purge rod from ball socket in piston shaft then remove purge rod.

ti14481a

9.Inspect fluid housing o-rings for wear or damage. Replace if necessary.

313872B

33

Page 33
Image 33
Graco Inc 24C932, 313872B, 257999, 24C934, 24C933, TI14450a Remove Front End, Perform Pressure Relief Procedure