Maintenance

Replace Mix Chamber and Front Seal

19

17 18

ti14469a1

1.Use nut driver to open the Throat Seal Liquid bleed port and drain all Throat Seal Liquid or replace with empty cartridge.

ti14478a

FIG. 24: Open the Bleed Port

2.Follow Pressure Relief Procedure on page 22.

3.Close Throat Seal Liquid bleed port.

4.Use 5/16 in. nut driver (supplied) to remove orifices (25, 26, 27).

5.Use a 3/4 in. wrench to remove front pour tip (19).

6.Connect air quick coupler (AC).

7.Press and release trigger to push out the mix chamber (17) and front seal (18) and discard.

8.Disconnect air quick coupler (AC).

9.Install new mix chamber and front seal.

10.Replace front pour tip and torque to 60-70 in-lb (6.78-7.91 N•m).

NOTICE

To prevent cross-contamination of the orifices do not interchange A component and B component parts. The A component orifice is marked with an A.

11.Replace orifices. Torque to 20-30 in-lb (2.26-3.39 N•m).

12.Perform Replace Throat Seal Liquid Cartridge, page 31.