Maintenance
Replace Mix Chamber and Front Seal
19
17 18
ti14469a1
1.Use nut driver to open the Throat Seal Liquid bleed port and drain all Throat Seal Liquid or replace with empty cartridge.
ti14478a
FIG. 24: Open the Bleed Port
2.Follow Pressure Relief Procedure on page 22.
3.Close Throat Seal Liquid bleed port.
4.Use 5/16 in. nut driver (supplied) to remove orifices (25, 26, 27).
5.Use a 3/4 in. wrench to remove front pour tip (19).
6.Connect air quick coupler (AC).
7.Press and release trigger to push out the mix chamber (17) and front seal (18) and discard.
8.Disconnect air quick coupler (AC).
9.Install new mix chamber and front seal.
10.Replace front pour tip and torque to
NOTICE
To prevent
11.Replace orifices. Torque to
12.Perform Replace Throat Seal Liquid Cartridge, page 31.
30 | 313872B |