HandyTone-486 User Manual

Grandstream Networks, Inc.

Disable Call-

Waiting:

Send DTMF:

DTMF Payload Type:

Send Flash Event: FXS Impedance:

Caller ID Scheme:

Onhook Voltage:

No

Yes

 

 

in-audio

 

via RTP (RFC2833)

via SIP INFO

101

 

 

 

No

Yes

(Flash will be sent as a DTMF event if set to Yes)

current setting is " 600 Ohm (North America)"

current setting is " Bellcore"

current setting is " 36V"

Polarity Reversal:

NTP Server:

Send Anonymous:

Lock keypad update:

No Yes

time.nist.gov

No Yes

No Yes

(reverse polarity upon call establishment and termination) (URI or IP address)

(caller ID will be blocked if set to Yes)

(configuration update via keypad is disabled if set to Yes)

Special Feature:

WAN Side HTTP

Access:

PSTN Access Code:

Syslog Server:

current setting is "Standard"

No

Yes (WAN side access to http server will be rejected if set to No)

 

(key pattern to use the PSTN line, default is "*00")

Syslog Level:

current setting is "NONE"

 

 

Update

Cancel Reboot

 

All Rights Reserved Grandstream Networks, Inc. 2005

Admin Password

Administrator password. Only administrator can configure the “Advanced Settings” page.

 

Password field is purposely blanked for security reason after clicking update and saved. The

 

maximum password length is 25 characters.

SIP Server

IP address or Domain name provided by VoIP service provider

Outbound Proxy

IP address or Domain name of Outbound Proxy, or Media Gateway, or Session Border

Controller. Used by ATA for firewall or NAT penetration in different network environment. If

 

symmetric NAT is detected, STUN will not work and ONLY outbound proxy will provide

 

solution for it.

 

SIP User ID

User account information, provided by VoIP service provider (ITSP), usually has the form of

 

digit similar to phone number or actually a phone number

Authenticate ID

ID used for authentication, usually same as SIP user ID, but could be different and decided by

 

ITSP.

 