Depth-Of-Cut Scale

 

Fence Stops

 

 

 

 

 

 

To set the depth-of-cut scale:

1.Set the outfeed table height as described in the ÒOutfeed Table HeightÓ sub-section.

2.Place a straightedge across the infeed and outfeed tables

3.Adjust the infeed table until it is level with the outfeed table.

4.Adjust the depth-of-cut pointer to read Ò0Ó (Figure 29).

Figure 29. Depth-of-cut pointer adjusted to Ò0Ó position.

The fence stops are adjustable nuts and bolts that simplify the task of adjusting the fence to 45û inward, 90û, and 45û outward (135û).

To set the 45˚ inward fence stop :

1.Using a 45û square, adjust the fence to the 45û inward position.

2.Loosen the jam nut shown in Figure 30.

Fence Stop Nut

Jam Nut

Figure 30. 45û inward fence stop jam nut.

3.Adjust the 45û inward fence stop nut until it makes contact with the back of the fence bracket.

4.Retighten the jam nut loosened in step 2.

-32-

G0526 6" Jointer

Page 34
Image 34
Grizzly G0526 Depth-Of-Cut Scale Fence Stops, To set the depth-of-cut scale, To set the 45˚ inward fence stop