Grizzly G0705 owner manual Jumper positions on terminal block

Models: G0705

1 60
Download 60 pages 44.75 Kb
Page 15
Image 15

4.Remove the screws that secure the brass contactor mounting plate to the back of the electrical box, then pull the contactors out to access the gray tab shown in Figure 7. Pull outward on the gray tab to release each contactor from the mounting plate.

Mounting Plate

Gray Tab

Figure 7. Contactor release tab location.

5.Install the two 110V contactors from the Model G0705 110V Conversion Kit in place of the contactors you removed in Step 4.

6.Replace the wires you removed in Step 3 to the corresponding terminals on the 110V con- tactors. The wiring is the same for 110V and 220V. Refer to SECTION 8: WIRING starting on Page 45 for detailed wiring diagrams.

7.Locate the indicator lamp shown in Figures 4 & 5. Disconnect the two wires from its termi- nals, then remove the lamp.

8.Install the 110V indicator lamp from the Model G0705 110V Conversion Kit in place of the lamp you removed in Step 7.

9.Connect the wires you removed in Step 7 to the corresponding terminals on the 110V indi- cator lamp. The wiring is the same for 110V and 220V.

Model G0705 (Mfg. since 09/09)

10.Locate the terminal block located in the motor junction box, shown in Figure 8.

Motor 220V

Terminal Block

110V Terminal Block Jumper Position. (Wire positions are the same for 110V/220V)

U1

Z2

Run

 

U1

Z2

 

Start

 

W2

Capacitor

U2

 

W2

 

Capacitor

 

20 MFD

V1

V2

150 MFD

V1

U2

 

U2

 

 

450 VAC

 

 

 

 

250 VAC

Z1

 

 

 

 

 

 

 

 

 

 

V1

 

 

U1

 

W1

 

 

 

W1

V2

 

 

PE

Ground

 

 

 

 

 

 

 

Jumpers Moved

 

220V

Jumper

 

 

 

 

 

for 110V

 

Location

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 8. Jumper positions on terminal block.

-13-

Page 15
Image 15
Grizzly G0705 owner manual Jumper positions on terminal block