14.Secure table cable bracket underneath left end of table with (2) M10-1.5 x 25 cap screws, as shown in Figure 20.

Cable

Bracket

x 2

Figure 20. Cable bracket installed.

15.Thread hex bolt attached to end of cable into cable bracket until cable tension is enough to keep cable tightly wrapped around pulley (see Figure 21).

Hex Bolt

Jam Nut

Figure 21. Cable attached to cable bracket.

16.Tighten jam nut against bracket to secure position of hex bolt.

17.Attach table ends to table with (4) M8-1.25 x 12 cap screws (see Figure 22).

2

of 4

Table

End

Figure 22. Table end attached.

18.Stone and clean any burrs from unpainted table surface and bottom of magnetic chuck, then apply a thin coat of ISO 32 oil to both surfaces.

19.With help from another person, position magnetic chuck in center of table with chuck control facing to front, as shown in Figure 23.

Chuck Control

Clamp Assemblies

Figure 23. Magnetic chuck attached to table.

20.Secure magnetic chuck to table with (2) clamp assemblies, as shown in Figure 23.