Rewire To 440V (G9953ZXF Only)

To rewire the Model G9953ZXF to 440V:

1.Disconnect the sander from the power source!

2.Replace the power indicator light in the pedestal switch to one suitable for 440V operation

3.Remove the RHN-18 overload relay and replace it with a RHN-10 (5.5-8.5A) type, with the dial set to 7A (Figure 4).

7

RHN-10

Overload Relay

Figure 4. Overload relays.

4.Remove the CN-18 magnetic contact over- load relay and replace it with a CN-11 type (Figure 5).

CN-11

Magnetic

Contactor

Overload

Relay

11

Figure 5. Overload relays.

5.Wire the motor as shown on the diagram on the inside of the motor wire cover. Note— The circled references on the diagrams rep- resent labels on the wires. Also, Figure 6 below has been provided for your reference and are current at the time that this manual is being written. However, always use the dia- gram on the wire cover that comes with your motor!

G9953ZXF

Motor Wiring

4

5

6

4

5

6

7

8

9

7

8

9

1

2

3

1

2

3

R S T

R S T

220V

440V

Figure 6. 440V motor wiring.

 

 

 

 

 

 

 

 

 

 

 

 

-10-

 

Ultimate Series Jointers

Page 12
Image 12