Step 5

Strip the ends of the low voltage wire and twist tightly. Attach these ends to the 18 VAC OR SOLAR terminals located on the POWER INPUTS terminal block.

Be certain not to let the exposed wires touch each other!

Insert one transformer wire into an 18 VAC OR SOLAR terminal. Insert the other transformer wire into the remaining 18 VAC OR SOLAR terminal. The transformer wires can be connected

CONTROL OUTPUTS

POWER

LOCK

AUX

INPUT

PWR

RLY

 

 

18 VAC

LOCK

AUX

OR

PWR

RLY

SOLAR

 

 

~ ~

 

 

2ND OPERATOR

GRN WHT BLUE BRN ORG RED BLK

2ND OPERATOR

MASTER OPERATOR

GRN WHT BLUE BRN ORG RED BLK

MASTER OPERATOR

to the 18 VAC OR SOLAR terminals regardless of color/polarity.

Tighten set screws against exposed end of wires.

Low Voltage Wire from AC Transformer or Solar Panel

BLACK

RED

Power Cable from Master Arm

Step 6

At the transformer, strip 1/2” of insulation from the ends of the low voltage wire. Attach wires to the transformer terminals.

Make sure the exposed wires do not touch each other!

DO NOT PLUG THE TRANSFORMER INTO AN OUTLET DURING THIS STEP! THE TRANSFORMER MUST ONLY BE PLUGGED INTO AN OUTLET DURING STEP 3 (page 15)!

Connect Battery

Step 1

Make sure the control box power switch is OFF. Remove the control box cover and slide the battery into position (terminals to the right).

ON/OFF Switch

14GTO 4000XLS Instruction Manual © 01.10.12

Page 24
Image 24
GTO R4854 01, 10, 12 installation manual Connect Battery, Be certain not to let the exposed wires touch each other