Set Control Board for Push-To-Open

Make sure the control box power switch is OFF. Use a small screwdriver to move the Number 3 DIP switch from the factory setting (OFF / Pull-To-Open) to ON for Push-To-Open. Turn power switch ON. The control board is now configured to push the gate open.

 

 

 

 

 

FORCE

MAX

ON ON

PUSH SIMULT.

ON

ON

 

 

 

 

 

STALL

MIN

ON

DIP

 

 

ON

 

 

 

ON

TIMECLOSEAUTO

OFF120

1 2 3 4

MODE1OFF

OFF

 

 

 

 

STARTSOFTOFF WARNINGOFF

OPENPULL OPEN2ND..DLY

1

2

3

4

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIP#3

ON: Push-to-open operation.

OFF: Pull-to-open operation (factory setting).

Setting the Open Position Limit (Push-To-Open Installations)

Step 1

Gate in Closed

Power switch is on, gate is

Postion

in the CLOSED position,

 

operator arm

 

fully retracted.

Control

 

 

Box

ON/OFF Switch

 

Step 2

Press the transmitter to activate operator arm. The gate will begin to OPEN.

Control

Box

Gate

Opening

Step 3

 

 

When the gate reaches

Gate

 

the desired OPEN

Control

position, press the

Opened

Box

 

transmitter to

 

 

stop the gate.

 

 

Step 4

 

 

With the master

 

gate at the correct

T.

 

position, program the

 

open limit setting by

 

 

pressing and holding

 

LEARN MAST LIMIT.

 

 

S3

LEARN

MAST LIMIT S2

LEARN

2ND LIMIT S4

Learn Master Limit Button

Step 5

Press the transmitter again to allow the gate to return to the fully CLOSED position.

Gate is now programmed

Gate in Closed

 

Postion

 

Gate open position

 

is now programmed

Control

 

Box

The gate open position is now programmed. If you make a mistake and set the limit at the wrong position: press your transmitter to return the gate to the fully closed position, then press and hold the LEARN MAST LIMIT button for 5 seconds. This will clear the memory for the open limit position. Repeat Steps 1-5.

22GTO 4000XLS Instruction Manual © 01.10.12

Page 32
Image 32
GTO 12, R4854 01, 10 Set Control Board for Push-To-Open, Setting the Open Position Limit Push-To-Open Installations