Step 2

 

IMPORTANT: Connect the BLACK battery wire to the NEGATIVE (–)

 

battery terminal. Connect the RED battery wire to the POSITIVE (+)

 

terminal. Reverse connection of battery wires will damage the

 

control board.

 

 

BLACK

 

RED

Step 3

BLACK wire to NEGATIVE () terminal

RED wire to POSITIVE (+) terminal

Plug the transformer

into the electrical outlet. (Use of a surge protector with the transformer is strongly recommended.) IMPORTANT: This is a class II indoor transformer; if using transformer outdoors be sure to enclose it in a weatherproof case.

Control Board Settings

Set Closed Position Limit (for Pull-To-Open Applications)

Step 1

 

Gate in

Power switch is on, gate

 

OPEN

is in the OPEN position,

Control

Postion

Box

operator arm

 

 

fully retracted.

 

 

 

ON/OFF Switch

 

Step 2

Press the transmitter to activate operator arm. The gate will begin

to CLOSE.

Gate

Closing

Control

Box

Step 3

 

 

When the gate reaches

 

 

the desired CLOSED

Control

Gate

Box

position, press

 

Closed

the transmitter

 

 

to stop the gate.

 

 

Step 4

 

 

With the gate at the

 

correct position,

T.

 

program the closed

 

limit setting by

 

 

pressing and holding

 

LEARN MAST LIMIT.

 

 

S3

LEARN

MAST LIMIT S2

LEARN

2ND LIMIT S4

Learn Master Limit Button

Step 5

Press the transmitter again to allow the gate to return to

the fully OPEN position.

 

Gate in

 

OPEN

Control

Postion

Box

The gate closed position is now programmed. If you make a mistake and set the limit at the wrong position: press your transmitter to return the gate to the fully opened position, then press and hold the LEARN MAST LIMIT button for 5 seconds. This will clear the memory for the closed limit position. Repeat Steps 1-5.

GTO 4000XLS Instruction Manual © 01.10.12 15

Page 25
Image 25
GTO 10, R4854 01, 12 Control Board Settings, Set Closed Position Limit for Pull-To-Open Applications, To Close