7. Installation Overview

Pull-To-Open Gates (Gate Opens into the Property)

The diagram shown below is an example of a Pull-To-Open installation on a chain link fence and single gate. Mounting the operator on a masonry column requires special procedures; see Column Installation Information on page 23. Furthermore, if you have a Push-To-Open gate, see Push-To-Open Installation on page 21 before proceeding.

Receiver

Control Box with Battery

120 Volt indoor Transformer

(surge protector not supplied)

Run 1000' (max.) of low voltage wire to control box from transformer (wire not included).

Gate Swings Evenly and Freely

Horizontal Cross Member

Hung Firmly and Plumb

Post Bracket Assembly

 

Single Gate Opener

 

Warning Sign

Gate Bracket

 

Power Cable

 

 

Closed Position Stop Plate

Fence Post Set in Concrete

PVC conduit (not included) to protect wire from lawn mowers and weed eaters.

Install the Operator

Install the Post Bracket Assembly

The post bracket is designed to work on a flat post. Posts must be at least 6” square in order to bolt the post bracket. When using bolts to mount the post bracket, the bolts must completely penetrate the post.

• The best method of attaching the post bracket to a metal post is welding.

• If your post exceeds 8”, it will be necessary to use hex head bolts longer than those supplied.

• Round wood posts (no smaller than 8” diameter) may be notched to create a flat surface for attaching the post bracket.

• Wood posts will require a metal plate (not provided) between the nuts and post to prevent the operator from pulling the bolts and washers through the wood.

A post smaller than 6” in diameter should be made of metal instead of wood so that it will remain stable while the operator is moving the gate.

Masonry columns will require masonry anchors/ hardware (not provided).