Generation 3 Visual Feedback
SYMPTOM | DIAGNOSIS | CHECK: |
Status (clear)1 blink | Cycle Terminal | • Disconnect the push button, keypad, intercom keypad, or |
| Shorted | any other accessory wired to this terminal. |
|
| • Try the remote. If the remote works, then the problem is |
|
| the accessory. |
Status (clear) 2 | Safety Terminal | • Disconnect the loop detector, photo beam, or any other |
blinks | Shorted | accessory wired to this terminal. |
|
| • Try the remote. If the remote works, the problem is the |
|
| accessory. |
Status (clear) 3 | Exit Terminal | • Disconnect exit wand, loop detector, photo beam, or any |
blinks | Shorted | other accessory wired to this terminal. |
|
| • Try remote. If the remote works, the problem is the |
|
| accessory. |
Status (clear) 4 | Shadow Terminal | • Disconnect the loop detector, photo beam, or any other |
blinks | Shorted | accessory wired to this terminal. |
|
| • Try remote. If the remote works, the problem is the |
|
| accessory. |
Status (clear) 5 | Close Edge | • Disconnect the edge sensor, photo beam, or any other |
blinks | Terminal Shorted | accessory wired to this terminal. |
|
| • Try the remote. If the remote works, the problem is the |
|
| accessory. |
Status (clear) 6 | Open Edge | • Disconnect edge sensor, photo beam, or any other |
blinks | Terminal Shorted | accessory wired to this terminal. |
|
| • Try the remote. If the remote works, the problem is the |
|
| accessory. |
RF (yellow) Flickers | Receiving 318 MHz | • Normal operation when remote or wireless keypad is used. |
| RF |
|
RF (yellow)OFF | No 318 MHz RF | • Battery in Remote |
| Received | • Program Remote |
|
| • Antenna Receiver Connections |
|
| • Antenna Receiver |
|
|
|
Power (green) | AC or Solar Power | • Normal Operation |
ON | Present |
|
|
| |
|
|
|
VOLTAGE READINGS
18 Vac Transformer | 18.0 to 22.0 Vac |
10 W Solar panel (single) | 18.0 to 22.0 Vdc |
In FULL SUN — measure voltage with the Solar Panel Disconnected. | |
12 V, 7 amp hour Battery | 12.5 to 13.5 Vdc |
or Two 12V, 7 amp hour Batteries if using solar power |
|
Measure voltage at battery terminals with battery disconnected | |
Charging circuit | 12.0 to 14.8 Vdc |
Measure voltage at battery terminals with battery connected