Troubleshooting Guide

If your gate operator does not function properly after it is installed, use this guide before calling the GTO Service Department.

Generation 3 Audible Feedback

SYMPTOM

DIAGNOSIS

CHECK:

 

 

 

1 short beep upon

Circuit Board

• Normal Operation

power up

Powered Up &

 

 

Ready

 

 

 

 

1 short beep upon

Blown Fuse

• Fuse

activation

Low or Bad Battery

• Battery Under Load

 

• Battery Harness Connections

 

Loose Battery

 

 

 

Connection

 

Continuous

Circuit Board

• Path of Gate

Uninterrupted

Senses an

• Gate for Level and Plumb

Alarm

Obstruction

• Stall Force Adjustment

 

 

• Disconnect Safety Devices

 

 

• Rev Counter

 

 

 

1 beep with 10

Low Battery

• Fuses

seconds off

Condition

• Battery Harness Connections

 

 

• Battery Under Load

 

 

 

1 beep then 2

Master Motor

• Connections to Master Inputs

beeps

Terminals Shorted

• Master Arm Power Cable

 

 

• Motor

 

 

• Circuit Board

 

 

 

1 beep with 2

Master Arm Limit

• Connections to Master Inputs

seconds off

Switch Error

• Master Arm Power Cable

 

 

 

3 beeps with 2

Master Arm Rev

• Connections to Master Inputs

seconds off

Counter Error

• Master Arm Power Cable

 

 

• Rev Counter

 

 

 