3.11.11 CAUTION

Figure 3-8Limit Switch Components – 25 Ton TCR25000C2 and TCR25000P2

3.11.5Measure and record the “K” dimension of all hooks on hoist. See Table 5-6under Section 5, “Inspection”. Always use the same side of the hook to measure and record the "K" dimension.

3.11.6Record the hoist Code Number and Serial Number (from the nameplate on the hoist – see Section 10) in the space provided on the cover of this manual.

3.11.7Ensure that the hoist is properly installed to either a fixed point, or trolley, whichever applies.

3.11.8If hoist is installed on a trolley, ensure that

trolley is properly installed on the beam, and

stops for the trolley are correctly positioned and securely installed on the beam.

3.11.9Ensure that all nuts, bolts and split (cotter) pins are sufficiently fastened.

3.11.10For hoists with pendant controls, Ensure that the Pendant Hoses and Strain Relief Chain are properly attached to the hoist. See Section 7.4.

Check Air Supply - Check air supply before everyday use. Ensure proper air quality and air pressure.

3.11.12 CAUTION Check the lubricator for proper function and adequate oil level. 3.11.13 Confirm proper operation.

Before operating read and become familiar with Section 4 - Operation.

Before operating ensure that the hoist (and trolley) meets the Inspection, Testing and Maintenance requirements of ANSI/ASME B30.16.

Before operating ensure that nothing will interfere with the full range of the hoist’s (and trolley’s) operation.

3.11.14 Proceed with trial operation to confirm proper operation.

Initially operate slowly under no load in both directions. Verify controls agree with hoist direction. Perform inspections per Section 5.3, “Frequent Inspections”.

18

Page 18
Image 18