Harrington Hoists TCR owner manual Technical Information, Specifications

Models: TCR

1 44
Download 44 pages 59.94 Kb
Page 8
Image 8

2.0Technical Information

2.1Specifications

2.1.1 Product Code

2.1.2Operating Conditions and Environment

Temperature range:

+14° to +140°F (-10° to +60°C)

Relative Humidity:

85% or less

Supply Air:

60 to 90 pounds per square inch

Air Consumption:

170 to 220 cubic feet minute

Air Lubrication Requirements:

Minimum 10 to 15 drops per minute (2-3 cc/min) of oil

Air Filtration Requirements:

Maximum 5 micron air filter or finer

Load Limiter:

Adjustable; Factory set to 125% of rated capacity

Pendant

Model

Cord

Model

Table 2-1Hoist Specifications

 

 

 

Push

Up/Down Speeds

Up/Down

Load Chain

 

Weight for

 

 

Standard

Air Consumption Rates

Diameter

Net

Cap.

Product

Button

 

 

Additional

(ft/min @ 90 psi)

 

 

(mm)

Lift

Hose

(cubic ft/min @ 90 psi)

Weight

One Foot

(Tons)

Code

 

 

x

 

 

(ft)

L

 

 

 

 

Chain Fall

(lbs)

of Lift

 

 

 

(ft)

No Load

w/Full Load

No Load

w/Full Load

 

(lbs)

 

 

 

Lines

 

 

 

 

 

 

 

 

 

 

 

10

TCR10000P2

10

8.8

7.2/5.9

5.1/7.6

220/180

180/210

16 x 2

476

3.8

 

 

 

 

 

 

 

 

 

 

25

TCR25000P2

9.4

2.1/1.6

1.8/2.2

210/190

170/200

22 x 2

1082

7.0

 

10

TCR10000C2

10

8.1

7.2/5.9

5.1/7.6

220/180

180/210

16 x 2

465

3.8

 

 

 

 

 

 

 

 

 

 

25

TCR25000C2

8.7

2.1/1.6

1.8/2.2

210/190

170/200

22 x 2

1074

7.0

 

 

 

 

 

 

 

 

 

 

 

 

8

Page 8
Image 8
Harrington Hoists TCR owner manual Technical Information, Pendant Model Cord 1Hoist Specifications