5.5Occasionally Used Hoists

5.5.1 Hoists that are used infrequently shall be inspected as follows prior to placing in service:

Hoist Idle More Than 1 Month, Less Than 1 Year: Inspect per FREQUENT Inspection criteria of Section 5.3 above.

Hoist Idle More Than 1 Year: Inspect per PERIODIC Inspection criteria of Section 5.4 above.

5.6Inspection Records

5.6.1Dated inspection reports and records should be maintained at time intervals corresponding to those that apply for the hoist’s PERIODIC interval per Section 5.2.4. These records should be stored where they are available to personnel involved with the inspection, maintenance, or operation of the hoist.

5.6.2A long range chain inspection program should be established and should include records of examination of chains removed from service so a relationship can be established between visual observation and actual condition of the chain.

5.7Inspection Methods and Criteria

5.7.1This section covers the inspection of specific items. The list of items in this section is based on those listed in ANSI/ASME B30.16 for the Frequent and Periodic Inspection. In accordance with ANSI/ASME B30.16, these inspections are not intended to involve disassembly of the hoist. Rather, disassembly for further inspection would be required if frequent or periodic inspection results so indicate. Such disassembly and further inspection should only be performed by a qualified person trained in the disassembly and re-assembly of the hoist.

Table 5-3Hoist Inspection Methods and Criteria

Item

Method

Criteria

Action

 

 

 

 

Functional operating

Visual, Auditory

Mechanisms should be properly adjusted and

Repair or replace

mechanisms.

 

should not produce unusual sounds when

as required.

 

 

operated.

 

Limit Switch

Function

Proper operation. Actuation of limit switch should

Repair or replace

 

 

stop hoist.

as required.

 

 

 

 

Chain Lever/Limit

Visual, Function

Lever should not be bent or significantly worn and

Replace.

Lever Assembly

 

should be able to move freely.

 

Braking System

Function

Braking distance should not exceed

Repair or replace

 

 

approximately five chain links.

as required.

Hooks - Surface

Visual

Should be free of significant rust, weld splatter,

Replace.

Condition

 

deep nicks, or gouges.

 

 

 

 

 

Hooks - Fretting

Measure

The “u” dimension should not be less than

Replace.

wear

 

minimum value listed in Table 5-6.

 

Hooks - Stretch

Measure

The “K” dimension should not exceed the

Replace.

 

 

maximum value for replacement from Table 5-6

 

 

 

(See Section 3.11).

 

 

 

 

 

26