19Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07
Note: Use DVP Series
components only.
Note: Use DVP Series
components only.
Figure 5.13
INSTALLED
HORIZONTALLY
Figure 5.14
3. Rear Vent - Horizontal Termination- (continued)
Two elbows
V Minimum H1 Maximum H1 + H2 Maximum
0 ft. 0 mm 1-1/2 ft. 457 mm 2-1/2 ft. 762 mm
1 ft. 305 mm 3-1/2 ft. 1.1 m 6-1/2 ft. 2 m
2 ft. 762 mm 5-1/2 ft. 1.7 m 10-1/2 ft. 3.2 m
3 ft. 1.1 m 7-1/2 ft. 2.3 m 14 ft. 4.3 m
H1 + H2 MAX. =14 FT (4.3 m)
V1 + H1 + H2 MAX. = 40 FT (12.2 m)
V Minimum H1 Maximum H1 + H2 + H3 Maximum
0 ft. 0 mm 1-1/2 ft. 457 mm 2-1/2 ft. 762 mm
1 ft. 305 mm 3-1/2 ft. 1.1 m 6-1/2 ft. 2 m
2 ft. 762 mm 5-1/2 ft. 1.7 m 10-1/2 ft. 3.2 m
3 ft. 1.1 m 7-1/2 ft. 2.3 m 14 ft. 4.3 m
H1 + H2 MAX. =14 FT (4.3 m)
V1 + V2 + H1 + H2 MAX. = 40 FT (12.2 m)
3. Rear Vent - Horizontal Termination- Three elbows