Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/0716
Figure 5.7
NOTE: For vertical venting over 20 feet an extended vertical
baf e is recommended for improved ame appearance.

CAP

V1
V1 = 44 ft. Max. (13.4 m)Top Vent - Vertical TerminationNo ElbowsBaf e Instruction
1. Install the baf e over the center of the exhaust outlet in
the rebox (see Figure 5.8).
2. Center the exhaust opening in the open end of the
baf e, and secure through the slots on the baf e with
the 2-1/4 in. self tapping screws provided.
Baf es are recommended for these vertically terminated
products which have excessive draft. Baf es compensate
for high draft, restore visual ame height, and limit exces-
sive cooling resulting from too much secondary air. Refer
to the allowable vent con gurations in the model speci c
installer’s guide for recommended use of this baf e.
Note: Use SL D- Series
components only.
BAFFLE

VIEW FROM

UNDERNEATH

SIDE VIEW

FIREBOX
BACK
EXHAUST
FIREBOX
BACK
BAFFLE
FRONT
OF UNIT
Figure 5.8