Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/0714
E. Vent Diagrams

Fire Risk. Explosion Risk.

Do NOT pack insulation or other combustibles between ceiling restops.

ALWAYS maintain speci ed clearances around venting and restop systems.

Install wall shield and ceiling restops as speci ed.

Failure to keep insulation or other material away from vent pipe may cause re.

WARNING
NOTE: There MUST be a 25%
reduction in total H when using
ex vent except when using the
simple up and out installation
(see Figure 5.3).
Note: Use SL D- Series
components only.
V Minimum H1 Maximum
BE-36-C NG BE-36-C LP
90 Elbow Only 1-1/2 ft. 457 mm 1-1/2 ft. 457 mm
1/2 ft. 152 mm 2 ft. 610 mm 1-1/2 ft. 457 mm
1-1/2 ft. 457 mm 3 ft. 914 mm 3 ft. 914 mm
2-1/2 ft. 762 mm 5 ft. 1.5 m 5 ft. 1.5 m
3-1/2 ft. 1.1 m 7 ft. 2.1 m 7 ft. 2.1 m
4-1/2 ft. 1.4 m 15 ft. 4.6 m 15 ft. 4.6 m
H1 MAX. =15 FT (4.6 m)
V1 + H1 MAX. = 40 FT (12.2 m)
NOTE: There MUST be a 25%
reduction in total H when using
ex vent except when using the
simple up and out installation
(see Figure 5.3).
Note: Use SL D- Series
components only.
H2
H1
V1
Figure 5.4
Figure 5.5
1. Top Vent - Horizontal TerminationOne ElbowTwo Elbows
H1
V1
V Minimum H1 + H2 Maximum
BE-36-C NG BE-36-C LP
90 Elbow Only 1/2 ft. 152 mm 1/2 ft. 152 mm
1/2 ft. 152 mm 1 ft. 305 mm 1/2 ft. 152 mm
1-1/2 ft. 457 mm 2 ft. 610 mm 2 ft. 610 mm
2-1/2 ft. 762 mm 4 ft. 1.2 m 4 ft. 1.2 m
3-1/2 ft. 1.1 m 6 ft. 1.8 m 6 ft. 1.8 m
4-1/2 ft. 1.4 m 14 ft. 4.3 m 14 ft. 4.3 m
H1 + H2 MAX. =14 FT (4.3 m)
V1 + H1 + H2 MAX. = 40 FT (12.2 m)