Hearth and Home Technologies CD4842MR, CD4842MIR Install Vertical Termination Baffle, Flat Baffle

Models: CD4236MR CD4842MLR CD4236MLR CD4236MIR CD4236MILR CD4842MILR CD4842MIR CD4842MR

1 76
Download 76 pages 3.36 Kb
Page 32
Image 32

F. Install Vertical Termination Baffle

Note: For vertically terminated installations only.

Note: If installing a vertical vent/termination run off the top or rear of the appliance, the vertical termination baffle supplied with the appliance may be used.

Remove the glass (refer to Section 14.K.) to access the firebox and 5 in. inner flue.

Fold the baffle (Figure 7.17) to an approximate 90° angle (see Figure 7.18).

Figure 7.17 Flat Baffle

Figure 7.18 Baffle Bent to 90° Angle

Squeeze the open end of the bent baffle with one hand. Insert the baffle bent side up into the inner flue so that the bottom of the baffle is above the bead on the inside of the collar. See Figure 7.19.

Figure 7.19 Placing the Baffle

Release pressure on the baffle so that it is wedged against the sides of the flue collar. See Figure 7.20.

Figure 7.20 Baffle in Place

Replace the glass (refer to Section 14.K.).

Start the appliance.

32

Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev J • 06/08

Page 32
Image 32
Hearth and Home Technologies CD4842MR, CD4842MIR, CD4842MLR, CD4842MILR Install Vertical Termination Baffle, Flat Baffle