G. Vertical Termination

VERTICAL TERMINATION

CAP USE PART #SLK-991DA

STORM COLLAR

FLASHING

FIRESTOP

SUPPORT BOX

PIPE LENGTH

On vertical terminations use only Part #SLK-991DA or like components. See page 55.

Figure 5.10

1.Check the installation instructions for required 1 in. (25 mm) clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, or other nearby combustible surfaces. See page 16, Figure 5.15. Check the instructions for maximum vertical rise of the venting system, and any maximum horizontal offset limitations. All offsets must fall within the set parameters of the vent graph (Figure 5.2) located on page 12.

Note: Maximum vertical rise allowable is 40 ft. (10.7 m), Figure 5.11. Maximum number of 45º elbows permitted for a vertical installation is eight, provided their installation does not decrease maximum allowable horizontal run (as specified by vent graph, on page 12).

WARNING

Fire Risk. Explosion Risk.

Maintain vent clearance to combustibles as specified.

Do not pack air space with insulation or other materials.

Failure to keep insulation or other materials away from vent pipe may cause fire.

40 ft. (12 m)

MAXIMUM

Figure 5.11

2.Set the gas appliance in its desired location. Drop a plumb bob down from the ceiling to the position of the appliance flue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling, and mark the spot where the vent will penetrate the roof. Determine if ceiling joists, roof rafters, or other framing will obstruct the venting system. You may wish to relocate the appliance, or to offset, as shown in Figure 5.12 to avoid cutting load bearing members.

PLUMBER'S TAPE

CONNECTED TO

WALL STRAP

WALL

STRAP

TWO 45º

ELBOWS

Figure 5.12

16

Heat & Glo • Paloma • 7031-220 Rev. P • 10/08

Page 16
Image 16
Hearth and Home Technologies PALOMA-GR, PALOMA-BL, PALOMA-BZ, PALOMA-GY owner manual Vertical Termination