F. Horizontal Termination
TERMINATION CAP
90º ELBOW
PIPE LENGTH
WALL THIMBLE
WALL THIMBLE COVER
PIPE LENGTH
CHOOSE BETWEEN
SLIM LINE | OR | STANDARD |
WALL THIMBLE | WALL THIMBLE |
INTERIOR WALL
-2 IN. (51 MM)
CLEARANCE FROM REAR OF STOVE
CENTER LINE SNORKEL CAP
MINIMUM OF 6 IN. (152 MM) OF
PIPE THROUGH THE WALL
TRIM RING
SNORKEL CAP KIT
USED FOR HORIZONTAL VENT RUNS
WITH NO VERTICAL RISE.
Figure 5.3
1.Determine the desired location of the appliance. Check to ensure that wall studs or roof rafters are not in the way when the venting system is being planned. If this is the case, you may want to adjust the location of the appliance.
WARNING
Fire Risk
Exhaust Fumes Risk
Impaired Performance of Appliance
•Ensure vent components are locked together correctly.
•Pipe may separate if not properly joined.
2.Direct vent pipe is designed with a locking connection. To connect the venting system to the appliance flue outlet, a
3.Female ends of direct vent pipe/elbows are designed to slide straight onto the male ends of adjacent pipes by orienting the pipe indentations so they match and slide into the entry slots on the male ends, see Figure 5.4. Push the pipe sections completely together, then
FEMALE LOCKING LUGS
MALE LOCKING
Figure 5.4
WARNING
Fire Risk. Explosion Risk. Combustion Fume Risk.
Use vent run supports per installation instructions.
Connect vent sections per installation instructions.
•Maintain all clearances to combustibles.
•Do NOT allow vent to sag below connection point to appliance.
•Maintain specified slope (if required). Improper support may allow vent to sag or separate.
4.For installations using a round support box/wall thimble (check pipe manufacturer's instructions), mark the wall for a 10 in. x 10 in. (254 mm x 254 mm) square hole. The center of the square hole should line up with the center line of the horizontal pipe, as shown in Figure 5.5. Cut and frame the hole in the exterior wall where the vent will be terminated. If the wall being penetrated is constructed of noncombustible material, i.e. masonry block or concrete, a 7 in. (178 mm) diameter hole is acceptable.
Heat & Glo • Paloma • | 13 |