2 Getting Started
A. Design and Installation Considerations | C. Inspect Appliance and Components | ||||||
Heat & Glo direct vent gas appliances are designed to |
|
| WARNING | ||||
operate with all combustion air siphoned from outside of |
|
| |||||
the building and all exhaust gases expelled to the outside. |
|
| Inspect appliance and components for damage. | ||||
No additional outside air source is required. |
|
| |||||
|
|
|
|
|
| Damaged parts may impair safe operation. | |
|
| CAUTION |
|
| • Do NOT install damaged components. | ||
|
|
|
| • Do NOT install incomplete components. | |||
|
|
|
|
|
| ||
|
|
|
|
|
| • Do NOT install substitute components. | |
| Check building codes prior to installation. |
|
| Report damaged parts to dealer. | |||
| • Installation MUST comply with local, regional, state and |
|
|
| |||
| national codes and regulations. | • | Carefully remove the appliance and components from | ||||
| • Consult local building, fire officials or authorities having jurisdic- | ||||||
|
| the packaging. | |||||
| tion about restrictions, installation inspection, and permits. |
| |||||
| • | Remove door and set aside on protective surface. See | |||||
|
|
|
| ||||
When planning an appliance installation, it’s necessary to |
| page 44. | |||||
• | Remove log set and component pack from firebox. | ||||||
determine the following information before installing: | |||||||
• | Where the appliance is to be installed. | • | Report to your dealer any parts damaged in shipment, | ||||
• | The vent system configuration to be used. |
| particularly the condition of the glass. | ||||
• | Read all of the instructions before starting the insta- | ||||||
• | Gas supply piping. |
| |||||
|
| llation. Follow these instructions carefully during the | |||||
• | Electrical wiring. |
|
| ||||
|
| installation to ensure maximum safety and benefit. | |||||
• | Framing and finishing details. |
|
|
| |||
• | Whether optional |
|
| WARNING | |||
| wall switch, or remote |
|
| ||||
|
|
|
| ||||
|
|
|
|
|
| Hearth & Home Technologies disclaims any | |
|
|
| WARNING |
|
| responsibility for, and the warranty will be voided | |
|
|
|
|
| by, the following actions: | ||
| Keep appliance dry. |
| • | Installation and use of any damaged appliance or vent | |||
|
|
| system component. | ||||
| • | Mold or rust may cause odors. |
|
| |||
|
| • | Modification of the appliance or vent system. | ||||
| • | Water may damage controls. |
| ||||
|
| • | Installation other than as instructed by Hearth & Home | ||||
|
|
|
|
| |||
|
|
|
|
|
| Technologies. | |
B. Tools and Supplies Needed |
| • Improper positioning of the gas logs or the glass door. | |||||
Before beginning the installation be sure that the following |
| • Installation and/or use of any component part not approved | |||||
|
| by Hearth & Home Technologies. | |||||
tools and building supplies are available. |
|
| |||||
| Any such action may cause a fire hazard. | ||||||
Reciprocating saw | Framing material |
| |||||
|
|
| |||||
Pliers |
| Hi temp caulking material |
|
|
| ||
Hammer |
| Gloves |
|
|
| ||
Phillips screwdriver | Framing square |
|
|
| |||
Flat blade screwdriver | Electric drill and bits (1/4 in.) |
|
|
| |||
Plumb line |
| Safety glasses |
|
|
| ||
Level |
| Wrenches |
|
|
| ||
Ratchets/Sockets | Allen Wrench Set |
|
|
| |||
Manometer |
| Voltmeter |
|
|
| ||
Tape measure |
| 1/2 - 3/4 inch length, #6 or #8 |
One 1/4 inch female connection (for optional fan)
Noncorrosive leak check solution or combustible gas detector
6 | Heat & Glo • Paloma • |