Hearth and Home Technologies SL-550TV-IPI-E G. Fixed Glass Assembly, H. Install the Mesh

Models: SL-950TV-IPI-E SL-550TV-IPI-E SL-750TV-IPI-E

1 48
Download 48 pages 49.26 Kb
Page 37
Image 37
G. Fixed Glass Assembly

G. Fixed Glass Assembly

Removing Fixed Glass Assembly

WARNING! Risk of Asphyxiation! Handle fixed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches.

DO NOT strike, slam or scratch glass.

DO NOT operate fireplace with glass removed, cracked, broken or scratched.

Replace as a complete assembly.

Removing Fixed Glass Assembly

Pull the four glass assembly latches out of the groove on the glass frame. Remove glass door from the appliance (see Figure 14.3).

Replacing Fixed Glass Assembly

Replace the glass door on the appliance. Pull out and latch the four glass assembly latches into the groove on the glass frame.

LATCHES Removing Fixed Glass Assembly (BOTH BOTTOM

AND TOP)

GLASS

ASSEMBLY

Figure 14.3 Fixed Glass Assembly

H. Install the Mesh

The screen mesh is a protective barrier and must be at- tached to the appliance front/door.

I. Install Trim and/or Surround

Install optional trim kits and/or surrounds using the instructions included with the accessory.

Use non-combustible materials to cover the gap between the sheet rock and the appliance (when applicable to the model).

J. Install Hood

Hood is included with this appliance and required in all installations.

K. Air Shutter Setting

Air shutter settings should be adjusted by a qualified ser- vice technician at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shutter for longer vertical runs. See Figure 14.4.

Loosen the wing nut.

Push the air handle in to close the air shutter.

Pull the air handle out to open the air shutter.

Tighten the wing nut.

NOTICE: If sooting occurs, provide more air by opening the air shutter.

SHUTTER ADJUSTMENT

Figure 14.4 Air Shutter

Air Shutter Settings

Models

NG

LP

SL-550TV-IPI-E

Fully Closed

3/16 in.

SL-750TV-IPI-E

Fully Closed

3/16 in.

SL-950TV-IPI-E

3/16 in.

3/8 in.

Heat & Glo • SL-550 / 750 / 950TV-IPI-E2119-900 Rev. H • 11/08

37

Page 37
Image 37
Hearth and Home Technologies SL-550TV-IPI-E G. Fixed Glass Assembly, H. Install the Mesh, I. Install Trim and/or Surround