Top Vent - Horizontal Termination - (continued)

Two Elbows

6000C-IPI

 

 

 

V1 Minimum

H1 + H2 Maximum

Elbow only

Not allowed

6 in.

152 mm

2 ft.

610 mm

1 ft.

305 mm

4 ft.

1.2 m

1-1/2 ft.

457 mm

11 ft.

3.4 m

2 ft.

610 mm

19 ft.

3.8 m

2-1/2 ft.

762 mm

22 ft.

6.7 m

V1 + H1

+ H2 = 40 ft. (12.2 m) Maximum

H1 + H2 = 22 ft. (6.7 m) Maximum

V1 = 1 ft. (305 mm) Minimum

H2

H1

 

INSTALLED

HORIZONTALLY

 

 

 

 

 

8000C-IPI

 

 

 

 

 

 

 

 

 

 

 

 

 

V1 Minimum

H1 + H2 Maximum

 

 

 

 

 

Elbow only

Not allowed

 

 

 

6 in.

152 mm

Not allowed

 

 

 

1 ft.

305 mm

2 ft.

610 mm

 

 

 

2 ft.

610 mm

4 ft.

1.2 m

 

 

 

3 ft.

914 mm

6 ft.

1.8 m

 

 

 

4 ft.

1.2 m

8 ft.

2.4 m

 

 

 

6 ft.

1.8 m

12 ft.

3.6 m

 

 

 

10 ft.

3.0

20 ft.

6.1 m

 

 

 

V1

+ H1

+ H2 = 40 ft. (12.2 m) Maximum

 

 

 

 

 

H1 + H2 = 20 ft. (6.0 m) Maximum

 

 

 

 

 

V1 = 1 ft. (305 mm) Minimum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: For corner installations: A 6 inch

V

 

 

 

(152 mm) section of straight pipe may

1

 

 

need to be attached to the appliance

 

 

 

 

 

before a 90º elbow, to allow the vent

 

 

 

 

pipe to clear the top standoffs.

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 7.4

Three Elbows

H2

V1 Min.

H1 Max.

 

V2 Min.

H2 Max.

 

 

 

 

 

 

 

 

 

Elbow only

2 ft.

610 mm

0 in.

 

0 mm

1 ft.

305 mm

6 in.

152 mm

3 ft

914 mm

6 in.

 

152 mm

2 ft.

610 mm

1 ft.

305 mm

6 ft.

1.8 m

1 ft.

 

305 mm

6 ft.

1.8 m

 

 

 

 

 

 

 

 

 

2 ft.

610 mm

11 ft.*

3.4 m*

2 ft.

 

610 mm

10 ft.*

3.1 m*

 

 

 

 

 

 

 

 

 

3 ft.

914 mm

16 ft *

4.9 m*

3 ft.

 

914 mm

14 ft.*

4.3 m*

 

 

 

 

 

 

 

 

*H1 + H2 = 20 ft. (6.1 m) Maximum

V1 + V2 + H1 + H2 = 40 ft. (12.2 m) Maximum

 

 

 

 

 

 

 

 

 

V2

H1

V1

Figure 7.5

Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI2164-900 Rev. T • 9/12

29

Page 29
Image 29
Heat & Glo LifeStyle Top Vent Horizontal Termination Two Elbows, Three Elbows, 6000C-IPI V1 Minimum H1 + H2 Maximum