Rear Vent - Vertical Termination

One Elbow

V1

H1

Figure 7.17

V1 Minimum

H1 Maximum

6 in.

152 mm

2 ft.

610 mm

1 ft.

305 mm

3 ft.

914 mm

2 ft.

610 mm

5 ft.

1.5 m

3 ft.

914 mm

7 ft.

2.1 m

4 ft.

1.2 m

8 ft.

2.4 m

5 ft.

1.5 m

8 ft.

2.4 m

V1 + H1 = 40 ft. (12.2 m) Maximum

H1 = 8 ft. (2.4 m) Maximum

Two Elbows

V1

V1 Minimum

H1 + H2

Maximum

Back to Back 90º Elbows

3 ft.

 

914 mm

 

 

 

 

 

 

2 ft.

 

610 mm

6 ft.

 

1.8 m

4 ft.

 

1.2 m

9 ft.

 

2.7 m

 

 

 

 

 

 

6 ft.

 

1.8 m

12 ft.

 

3.7 m

8 ft.

 

2.4 m

15 ft.

 

4.6 m

 

V1 + H1 = 40 ft. (12.2 m) Maximum

H1 + H2 = 8 ft. (2.4 m) Maximum

INSTALLED

HORIZONTALLY H1

H2

Figure 7.18

Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI2164-900 Rev. T • 9/12

35

Page 35
Image 35
Heat & Glo LifeStyle 6000C manual Rear Vent Vertical Termination One Elbow, V1 Minimum H1 Maximum, Minimum + H Maximum