E

 

 

 

 

C

 

 

A

 

F

 

 

 

 

 

 

 

 

 

V

 

 

 

 

 

 

 

J

B

 

 

 

U.S

 

 

 

 

 

 

 

 

 

V

V

B

 

 

 

 

B

(3 FT.)

 

 

 

 

V

 

 

 

 

 

i

 

 

 

 

 

 

 

 

 

 

 

 

D

V

V

 

G

M

X

 

 

 

A

 

 

V

 

 

 

 

 

 

 

H or i

 

 

O

 

 

 

V

 

 

 

N

 

 

 

 

 

 

 

 

 

 

P

 

L

 

 

R

 

 

 

V

K

Electrical

K

V

 

 

 

 

Service

 

 

 

 

 

 

 

 

 

C

Q

V

(See Note 2)

Measure vertical clearances from this surface.

Measure horizontal clearances from this surface.

 

V

= VENT TERMINAL

X = AIR SUPPLY INLET

A

=

12 inches

clearances above grade, veranda,

 

 

 

(See Note 1)

porch, deck or balcony

B

=

12 inches

clearances to window or door

 

 

 

 

that may be opened, or to perma-

 

 

 

 

nently closed window. (Glass)

C

=

18 inches

vertical clearance to unventilated

 

 

 

 

soffit or to ventilated soffit located

 

 

 

 

above the terminal

 

 

 

30 inches

for vinyl clad soffits and below

 

 

 

 

electrical service

D

=

9 inches

clearance to outside corner

E

=

6 inches

clearance to inside corner

F

=

3 ft. (Canada)

not to be installed above a gas

 

 

 

 

meter/regulator assembly within 3

 

 

 

 

feet (90 cm) horizontally from the

 

 

 

 

center-line of the regulator

G

=

3 ft

clearance to gas service regulator

H

=

9 inches (U.S.A.)

vent outlet

 

 

 

 

12 inches (Canada) clearance to non-mechanical

 

 

 

(See Note 2)

air supply inlet to building or the

 

 

 

 

combustion air inlet to any other

i

=

3 ft. (U.S.A.)

appliance

 

 

 

 

6 ft. (Canada)

clearance to a mechanical (pow-

 

 

 

(See Note 2)

ered) air supply inlet

**a vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

***only permitted if veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the floor, or meets Note 2.

Note 1: On private property where termination is less than 7 feet above a sidewalk, driveway, deck, porch, veranda or balcony, use of a listed cap shield is suggested. (See vents components page)

Note 2: Termination in a covered alcove space (spaces open only on one side and with an overhang) are permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1. There must be 3 feet minimum between termination caps. 2. All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 feet below the termination cap. 3. All gravity air intakes within 3 feet of a termination cap must be a minimum of 1 foot below the termination cap.

Figure 6.4 Minimum Clearances for Termination

= AREA WHERE TERMINAL IS NOT PERMITTED

J**

=

7 ft

clearance above paved

 

 

(See Note 1)

sidewalk or a paved driveway

 

 

 

located on public property

K

=

6 inches

clearance from sides of electri-

 

 

(See Note 5)

cal service

L

=

12 inches

clearance above electrical

 

 

(See Note 5)

service

Covered Alcove Applications

M*** =

18 inches

clearance under veranda, porch,

 

 

 

 

deck, balcony or overhang

 

 

42 inches

......... vinyl

 

 

N

=

6 inches

non-vinyl sidewalls

 

 

12 inches

......... vinyl sidewalls

O

=

18 inches

......... non-vinyl soffit and overhang

 

 

42 inches

......... vinyl soffit and overhang

P

=

8 ft.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QMIN

RMAX

 

 

1 cap

 

3 feet

2 x Q ACTUAL

 

 

2 caps

 

6 feet

1 x Q ACTUAL

 

 

3 caps

 

9 feet

2/3 x Q ACTUAL

 

 

4 caps

 

12 feet

1/2 x Q ACTUAL

 

 

 

 

 

 

 

QMIN = # termination caps x 3 RMAX = (2 / # termination caps) x QACTUAL

Note 3: Local codes or regulations may require different clearances.

Note 4: Termination caps may be hot. Consider their proximity to doors or other traffic areas.

Note 5: Location of the vent termination must not interfere with access to the electrical service.

In the U.S and Canada: Vent system termination is NOT permitted in screened porches.

Vent system termination is permitted in porch areas with two or more sides open. You must follow all side walls, overhang and ground clearances as stated in the instructions.

Heat & Glo assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements.

CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED.

22

Heat & Glo • 6000GLX-IPI-S/-R, 6000GLX-IPILP-S/-R2101-900 Rev. Q • 11/08

Page 22
Image 22
Heat & Glo LifeStyle 6000GLX-IPI-S/-R, 6000GLX-IPILP-S/-R owner manual Covered Alcove Applications