E. Junction Box Installation

E. Junction Box Installation

If the box is being wired from the INSIDE of the appliance:

Remove the screw attaching the junction box/receptacle to the outer shell, rotate the junction box inward to disengage it from the outer shell (see Figure 12.2).

Pull the electrical wires from outside the appliance through the opening into the valve compartment and secure wires with a Romex connector. See Figure 12.2.

Make all necessary wire connections to the junction box/ receptacle and reattach the junction box/receptacle to the outer shell.

 

Romex

 

Connector

 

14/2WG

 

Cover Plate

 

outside firebox

WHT

 

BLK

 

WHT

 

BLK

Copper

 

GRN wire

ground attached

to GRN screw with

inside box

 

GRN wire

NOTICE: DO NOT wire

110 VAC to wall switch.

Figure 12.2 Junction Box Detail

 

F. Wall Switch Installation for Fan (Optional)

 

 

 

If the box is being wired to a wall mounted switch for use

 

 

 

with a fan (See Figure 12.3):

Minimum 14-3 AWG

 

Switch

The power supply for the appliance must be brought into

 

 

with Ground

 

 

 

a switch box.

 

Red

 

 

 

Black

Black

 

 

 

White

White

The power can then be supplied from the switch box to the

Junction Box

Green

Green

 

 

 

 

appliance using a minimum of 14-3 with ground wire.

Red Black White

Green

 

At the switch box connect the black (hot) wire and red

Power

 

Switch Box

 

Supply

 

(switch leg) wire to the wall switch as shown.

 

 

 

 

 

Wires

At the appliance connect the black (hot), white (neutral)

 

Knockout

 

 

and green (ground) wires to the junction box as shown.

 

 

 

• Add a 1/4 in. insulated female connector to the red (switch

Red

 

 

 

 

 

 

leg) wire, route it through the knockout in the face of the

 

 

 

 

junction box, and connect to the top fan switch connector

Figure 12.3 Junction Box Wired to Wall Switch or BC10

 

(1/4 in. male) as shown.

 

Heat & Glo • 6000GLX-IPI-S/-R, 6000GLX-IPILP-S/-R2101-900 Rev. Q • 11/08

49