Heat & Glo LifeStyle 6000GLX-IPILP-S/-R Rear Vent - Vertical Termination One Elbow, Two Elbows

Models: 6000GLX-IPI-S/-R 6000GLX-IPILP-S/-R

1 72
Download 72 pages 51.11 Kb
Page 31
Image 31
Rear Vent - Vertical Termination

Rear Vent - Vertical Termination

One Elbow

V1

V1 Minimum

H1 Maximum

6 in.

152 mm

2 ft.

610 mm

1 ft.

305 mm

3 ft.

914 mm

2 ft.

610 mm

5 ft.

1.5 m

3 ft.

914 mm

7 ft.

2.1 m

4 ft.

1.2 m

8 ft

2.4 m

5 ft.

1.5 m

8 ft

2.4 m

V1 + H1 = 40 ft (12.2 m) Maximum

H1 = 8 ft (2.4 m) Maximum

H1

Figure 7.17

Two Elbows

H1 + H2

Maximum

V1 Minimum

Back to Back 90º Elbows

3 ft.

 

914 mm

 

 

 

 

 

 

2 ft

 

610 mm

6 ft.

 

1.8 m

4 ft

 

1.2 m

9 ft.

 

2.7 m

 

 

 

 

 

 

6 ft.

 

1.8 m

12 ft.

 

3.7 m

8 ft.

 

2.4 m

15 ft.

 

4.6 m

V1

+ H1 = 40 ft (12.2 m) Maximum

H1 + H2 = 8 ft (2.4 m) Maximum

 

V2

INSTALLED

HORIZONTALLY H1

H2

Figure 7.18

Heat & Glo • 6000GLX-IPI-S/-R, 6000GLX-IPILP-S/-R2101-900 Rev. Q • 11/08