STEP 4.
Refer to the details in Figure 14.5 to position Optional Refractory Standoff Bracket.
Note: If fireplace is rear vented and has no elbows in the vent run, adjusting the refractory standoff bracket is allowed. If any elbows are used in the vent run, DO NOT adjust the refractory standoff bracket.
•Remove screw shown in Detail A.
•Bend down back flap along the two (2) perforations to break back flap from refractory standoff bracket. See Detail B.
•Rotate the separated piece and bend the back flap as shown in Detail C to enable the tabs to fit into the two
(2) holes on the left and right of the refractory standoffs indicated in Detail D.
•Verify that the back flap rests on top of left and right refractory standoff tabs noted in Detail E.
Refractory | Back Flap | Screw |
|
Standoff |
|
|
|
Bracket |
|
|
|
DETAIL A. |
|
|
|
DETAIL B. |
| DETAIL C. |
|
Left | Right | Left | Right |
DETAIL D. |
| DETAIL E. |
|
Figure 14.4 |
|
|
|
STEP 5.
Hold the top refractory with the brick pattern facing down. Bring the back edge into the firebox slightly higher than the front edge. Bring the back edge all the way to the metal back wall of the fireplace. Raise the front edge up until it clears the side refractory pieces. Drop the back edge down and nest the sides and back into the groove around the edges of the top piece of refractory.
Figure 14.5
F. Ember Placement
WARNING! Risk of Explosion! Follow ember placement instructions in manual. DO NOT place embers directly over burner ports. Replace ember material annually. Improperly placed embers interfere with proper burner operation.
Ember material is shipped with this gas appliance. To place the ember material:
•Embers CANNOT be placed directly over ports. Care should be taken not to cover the lighting trail of ports (from back to front).
•Place
EMBER MATERIAL |
Figure 14.6 Placement of Embers |
•Place Mystic Embers on areas of base refractory away from port holes. Use this material to give the appliance a realistic ash bed.
•Save the remaining ember materials for use during appliance servicing. The embers provided should be enough for 3 to 5 applications.
Heat & Glo • | 53 |