E. Vent Diagrams
Top Vent - Horizontal Termination
Note: The 6000/8000 series fireplaces can adapt to SLP series | WARNING | |
vent pipe, if desired. | Fire Risk. Explosion Risk. | |
When venting off the top of the unit, use a | ||
minimum 48 inch vertical section of SLP series vent pipe. | Do NOT pack insulation or other combustibles | |
A | between ceiling firestops. | |
section of SLP series vent pipe. | • ALWAYS maintain specified clearances around | |
After the 48 inch vertical section, the venting table rules must be | venting and firestop systems. | |
• Install wall shield and ceiling firestops as speci- | ||
followed. The first 48 inch vertical section is NOT counted as part | ||
of the vertical components in the table. It is still counted as part of | fied. | |
the overall maximum run. All venting table rules for the vent run | Failure to keep insulation or other material away | |
must still be followed. | from vent pipe may cause fire. | |
Example: DVP pipe 3 ft. min. vertical = 11 ft. max. horizontal | WARNING | |
SLP pipe 7 ft. min. vertical = 11 ft. max. horizontal | ||
| Fire Risk. | |
| • When using | |
| SS termination caps on top vented fireplaces, a | |
| 6 inch minimum vertical vent section is required | |
Top Vent - Horizontal Termination | before installing first elbow. | |
|
One Elbow
6000CMOD-IPI
V1 Minimum | H1 Maximum | |||
Elbow only | 2 ft | 610 mm | ||
6 in. |
| 152 mm | 4 ft. | 1.2 m |
1 ft. |
| 305 mm | 6 ft. | 1.8 m |
| 457 mm | 10 ft. | 3.0 m | |
2 ft. |
| 610 m | 15 ft. | 4.6 m |
| 762 mm | 18 ft. | 5.5 m | |
3 ft. |
| 914 mm | 20 ft. | 6.1 m |
V1 | + H1 = 40 ft. (12.2 m) Maximum | |||
| H1 = 20 ft. (6.1 m) Maximum |
8000CMOD-IPI
V1 Minimum | H1 Maximum | |||
Elbow Only | 2 ft. | 610 mm | ||
1 ft. |
| 305 mm | 3 ft. | 914 mm |
2 ft. |
| 610 mm | 6 ft. | 1.8 m |
3 ft. |
| 914 mm | 11 ft. | 3.4 m |
4 ft. |
| 1.2 m | 20 ft. | 6.1 m |
V1 | + H1 = 40 ft. (12.2 m) Maximum | |||
| H1 = 20 ft. (6.1 m) Maximum |
Note: For corner installations: A 6 inch (152
mm)section of straight pipe may need to be attached to the appliance before a 90º elbow, to allow the vent pipe to clear the top standoffs.
H1
V1
Figure 7.3
26 | Heat & Glo • |