Heat & Glo LifeStyle 8000CMOD-IPI E. Vent Diagrams, Top Vent - Horizontal Termination, One Elbow

Models: 6000CMOD-IPI 8000CMOD-IPI

1 71
Download 71 pages 38.11 Kb
Page 26
Image 26
E. Vent Diagrams

E. Vent Diagrams

Top Vent - Horizontal Termination

Note: The 6000/8000 series fireplaces can adapt to SLP series

WARNING

vent pipe, if desired.

Fire Risk. Explosion Risk.

When venting off the top of the unit, use a DVP-2SL adapter and a

minimum 48 inch vertical section of SLP series vent pipe.

Do NOT pack insulation or other combustibles

A DVP-SLP24 adapter may also be used with a 24 inch vertical

between ceiling firestops.

section of SLP series vent pipe.

• ALWAYS maintain specified clearances around

After the 48 inch vertical section, the venting table rules must be

venting and firestop systems.

• Install wall shield and ceiling firestops as speci-

followed. The first 48 inch vertical section is NOT counted as part

of the vertical components in the table. It is still counted as part of

fied.

the overall maximum run. All venting table rules for the vent run

Failure to keep insulation or other material away

must still be followed.

from vent pipe may cause fire.

Example: DVP pipe 3 ft. min. vertical = 11 ft. max. horizontal

WARNING

SLP pipe 7 ft. min. vertical = 11 ft. max. horizontal

 

Fire Risk.

 

• When using DVP-HRC-SS and DVP-HRC-ZC-

 

SS termination caps on top vented fireplaces, a

 

6 inch minimum vertical vent section is required

Top Vent - Horizontal Termination

before installing first elbow.

 

One Elbow

6000CMOD-IPI

V1 Minimum

H1 Maximum

Elbow only

2 ft

610 mm

6 in.

 

152 mm

4 ft.

1.2 m

1 ft.

 

305 mm

6 ft.

1.8 m

1-1/2 ft.

 

457 mm

10 ft.

3.0 m

2 ft.

 

610 m

15 ft.

4.6 m

2-1/2 ft.

 

762 mm

18 ft.

5.5 m

3 ft.

 

914 mm

20 ft.

6.1 m

V1

+ H1 = 40 ft. (12.2 m) Maximum

 

H1 = 20 ft. (6.1 m) Maximum

8000CMOD-IPI

V1 Minimum

H1 Maximum

Elbow Only

2 ft.

610 mm

1 ft.

 

305 mm

3 ft.

914 mm

2 ft.

 

610 mm

6 ft.

1.8 m

3 ft.

 

914 mm

11 ft.

3.4 m

4 ft.

 

1.2 m

20 ft.

6.1 m

V1

+ H1 = 40 ft. (12.2 m) Maximum

 

H1 = 20 ft. (6.1 m) Maximum

Note: For corner installations: A 6 inch (152

mm)section of straight pipe may need to be attached to the appliance before a 90º elbow, to allow the vent pipe to clear the top standoffs.

H1

V1

Figure 7.3

26

Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI2241-900 Rev. H • 5/12