5 Framing and Clearances

5 Framing and Clearances

A. Selecting Appliance Location

When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1).

WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.

Due to high temperatures, the appliance should be locat- ed out of traffic and away from furniture and draperies.

NOTICE: Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. Illustrations/diagrams are not drawn to scale. Actual installation may vary due to individual design preference.

NOTE: THE REAR STANDOFF MAY NEED TO BE REMOVED WHEN VENTING AT 45º

A

A. Selecting Appliance LocationF 60008000

1/2 IN.

A

BC

 

 

TOP VENT

 

ONE 90º ELBOW

B

ALCOVE INSTALLATION D

B

E

 

 

A

B

C

D

E

F

6000

in.

51

42

72

See Section D.

22

17-3/4

mm

1295

1067

1829

Mantel Projections

559

451

 

8000

in.

55-7/8

49

79

See Section D.

22

19-3/4

mm

1419

1245

2007

Mantel Projections

559

502

 

Figure 5.1 Appliance Locations