Safety Alert Key:

DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.

WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.

CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE: Used to address practices not related to personal injury.

Table of Contents

A. Congratulations

2

6 Termination Locations

 

B. Limited Lifetime Warranty

5

A. Vent Termination Minimum Clearances

23

 

 

1 Listing and Code Approvals

A. Appliance Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 B. Tempered Glass Specifications . . . . . . . . . . . . . . . . . . . . . 7 C. BTU Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . . 7 E. Non-Combustible Materials Specification. . . . . . . . . . . . . . 7 F. Combustible Materials Specification . . . . . . . . . . . . . . . . . 7 G. Electrical Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 H. Requirements for the Commonwealth of Massachusetts. . 8

User Guide

2 Operating Instructions

A. Gas Fireplace Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 B. Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 C. Fan Kit (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 D. Clear Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 E. Decorative Doors and Fronts . . . . . . . . . . . . . . . . . . . . . . 10 F. Fixed Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 G. Remote Controls, Wall Controls and Wall Switches. . . . . 10 H. IPI Battery Tray/Battery Installation . . . . . . . . . . . . . . . . . 11

I. Control Module Operation . . . . . . . . . . . . . . . . . . . . . . . . 11 J. Before Lighting Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . 11 K. Lighting Instructions (IPI) . . . . . . . . . . . . . . . . . . . . . . . . . 12 L. After Fireplace is Lit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 M. Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . 13

3 Maintenance and Service

A. Maintenance Tasks-Homeowner . . . . . . . . . . . . . . . . . . . 14

B. Maintenance Tasks-Qualified Service Technician . . . . . . 14

C. Glass Refractory, Base Pan, Burner and Valve

Assembly Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

D. Burner Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

7 Vent Information and Diagrams

A. Approved Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

B. Vent Table Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

C. Use of Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

D. Measuring Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

E. Vent Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

8 Vent Clearances and Framing

A. Pipe Clearances to Combustibles . . . . . . . . . . . . . . . . . . 32 B. Wall Penetration Framing. . . . . . . . . . . . . . . . . . . . . . . . . 32 C. Install the Ceiling Firestop . . . . . . . . . . . . . . . . . . . . . . . . 33 D. Install Attic Insulation Shield. . . . . . . . . . . . . . . . . . . . . . . 34 E. Installing the Optional Heat-Zone®Gas Kit . . . . . . . . . . . . . 34

9 Appliance Preparation

A. Top Vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

B. Installing the Non-combustible Board. . . . . . . . . . . . . . . . 36

C. Securing and Leveling the Appliance . . . . . . . . . . . . . . . . 36

10 Installing Vent Pipe (DVP and SLP Pipe)

A. Assemble Vent Sections (DVP Pipe Only) . . . . . . . . . . . . 37 B. Assemble Vent Sections (SLP Pipe Only) . . . . . . . . . . . . 38 C. Assemble Slip Sections . . . . . . . . . . . . . . . . . . . . . . . . . . 38 D. Secure the Vent Sections. . . . . . . . . . . . . . . . . . . . . . . . . 39 E. Disassemble Vent Sections . . . . . . . . . . . . . . . . . . . . . . . 39 F. Install Decorative Ceiling Components (SLP only). . . . . . 40 G. Install Metal Roof Flashing. . . . . . . . . . . . . . . . . . . . . . . . 41 H. Assemble and Install Storm Collar . . . . . . . . . . . . . . . . . . 41 I. Install Vertical Termination Cap . . . . . . . . . . . . . . . . . . . . 42 J. Install Decorative Wall Components (SLP only). . . . . . . . 42 K. Heat Shield Requirements for Horizontal Termination . . . 42 L. Install Horizontal Termination Cap (DVP and SLP Pipe) . 43

Installer Guide

4 Getting Started

A. Typical Appliance System. . . . . . . . . . . . . . . . . . . . . . . . . 18

B. Design and Installation Considerations . . . . . . . . . . . . . . 19

C. Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . . . 19

D. Inspect Appliance and Components. . . . . . . . . . . . . . . . . 19

5 Framing and Clearances

A. Selecting Appliance Location . . . . . . . . . . . . . . . . . . . . . . 20

B. Constructing the Appliance Chase . . . . . . . . . . . . . . . . . . 21

C. Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

D. Mantel and Wall Projections. . . . . . . . . . . . . . . . . . . . . . . 22

11 Gas Information

A. Fuel Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

B. Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

C. Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . 44

12 Electrical Information

A. Wiring Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 B. IntelliFire PlusTM Ignition System Wiring. . . . . . . . . . . . . . 45 C. Optional Accessories Requirements . . . . . . . . . . . . . . . . 45 D. Electrical Service and Repair . . . . . . . . . . . . . . . . . . . . . . 46 E. Junction Box Installation. . . . . . . . . . . . . . . . . . . . . . . . . . 46 F. Wall Switch Installation for Fan (Optional) . . . . . . . . . . . . 46

Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI2241-900 Rev. H • 5/12

3

Page 3
Image 3
Heat & Glo LifeStyle 6000CMOD-IPI, 8000CMOD-IPI owner manual Table of Contents, User Guide

6000CMOD-IPI, 8000CMOD-IPI specifications

The Heat & Glo LifeStyle 6000CMOD-IPI and 8000CMOD-IPI models represent the pinnacle of modern fireplace design, marrying aesthetics with advanced technology to create a unique heating experience. These versatile, linear gas fireplaces are designed to seamlessly integrate into any living space while offering exceptional performance and style.

One of the standout features of the LifeStyle series is its impressive heating efficiency. Both models utilize advanced heating technology to maximize warmth while minimizing energy consumption. The innovative IPI (Intermittent Pilot Ignition) system enhances efficiency by using a pilot light only when the fireplace is in use, ensuring that energy costs remain low.

The design of the LifeStyle series is both contemporary and customizable. Homeowners have the option to choose from various finishes, media styles, and decorative elements. The large, expansive viewing area enhances the ambiance of any room, showcasing the mesmerizing flames. The 6000CMOD-IPI with its 60-inch firebox and the 8000CMOD-IPI with an 80-inch firebox add a dramatic focal point to any setting.

Another significant innovation incorporated in these models is the use of advanced flame technology. This feature allows for an adjustable flame height, providing flexibility in terms of heat output and visual effects. Users can tailor the flames to suit mood and occasion, whether they desire a cozy ambiance for a quiet evening or a more robust heat output for entertaining.

The user-friendly controls add to the convenience of the LifeStyle series. Homeowners can easily operate the fireplace with a remote control or smart home integration, enabling adjustments from the comfort of their seating. Additionally, the fireplaces come equipped with a safety shut-off feature, providing peace of mind while enhancing user safety.

Maintenance is simplified with the LifeStyle series as well. The design minimizes creosote buildup and offers easy access for cleaning. The contemporary linear design also allows for easy installation, making it an appealing choice for both new builds and renovations.

In summary, the Heat & Glo LifeStyle 6000CMOD-IPI and 8000CMOD-IPI models combine cutting-edge heating technology, elegant design, and user-friendly features. These fireplaces not only serve as a source of comfort but also enhance the aesthetic appeal of any living space, making them a valuable addition for homeowners looking to elevate their interiors with warmth and style.