Heat & Glo LifeStyle BAY-40 2 Outside Air Inlet Locations, Lift To Open, Pull To Open, outside

Models: BAY-40

1 52
Download 52 pages 14.25 Kb
Page 14
Image 14
Figure 4.2 Outside Air Inlet Locations

3 ft min. from top of uppermost chimney section to air inlet.

Figure 4.2 Outside Air Inlet Locations

Attic insulation shield must be used to keep insulation away from chimney.

Ceiling firestop on floor of attic.

LIFT TO

OPEN

BAY-40

PULL TO

OPEN

PIER-40

Figure 4.4 Locating the Outside Air Control

NO

NO

 

Garage or

NO

Outlet blocked by

combustible

snow, leaves, etc.

liquids storage

Attic space

NO

Outlet placed

higher than 3 ft

below the

termination cap

YES

Factory-built

Clear area

fireplace

outside

 

house or in

 

ventilated

 

crawl space

Use only duct materials specified

 

by manufacturer (preferably with

 

short run or mainly straight duct,

 

except small dip for cold air trap

 

which will help prevent flow of cold air).

Figure 4.3 Outside Combustion Air Placement

14

Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07