C. Mantel

C. Mantel

A combustible mantel may be positioned no lower than 12 in. (305 mm) above the top of the fireplace opening. The combustible mantel may have a maximum depth of 12 in. (305 mm). Combustible trim pieces that project no more than 1-1/2 in.(38 mm) from the face of the fireplace can be placed no closer than 6 in. (152 mm) from the top of the fireplace opening. See Figure 8.4. Combustible trim must not cover the metal surfaces of the fireplace. This mantel clearance is in accordance with Section 7-3.3.3 of ANSI/ NFPA211.

D.Sidewalls/Surrounds WARNING

Fire Risk

Do NOT obstruct air inlets.

Finishing materials must not interfere with:

Air flow through inlets

Operation of doors

Access for service

D.Sidewalls/Surrounds

Adjacent combustible side walls must be located a minimum of 12 in. (305 mm) from the fireplace opening. If you are us- ing a decorative surround constructed of combustible ma- terial, it must be located within the shaded area defined in Figure 8.5. Short stub walls are also acceptable if they are contained within the shaded area.

E. Glass Doors

This fireplace has been tested and listed with doors (re- quired). See Section 12B Fireplace Components for avail- able doors. Please refer to the manual packed with each set of doors for installation instructions.

 

12 in. (305 mm)

 

 

 

 

max.

 

1-1/2 in. (38 mm) max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Header

Mantel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standoff

12 in. (305 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top of

Fireplace

Opening

6 in. (152 mm) min.

Figure 8.4 Mantel Specifications

 

 

 

62 in.

 

 

 

12 in.

 

 

 

 

 

 

 

 

 

 

 

(305 mm)

 

 

 

(1575 mm)

 

 

72 in.

 

16 in.

 

 

from opening

 

 

 

 

 

 

 

of fireplace

 

 

(1829 mm)

 

(406 mm)

 

 

 

 

 

 

 

16 in.

(406 mm)

40-1/2 in.

56 in.

(1029 mm)

(1422 mm)

 

26 in.

6 in.

 

(660 mm)

(152 mm)

HEARTH

to front of

HEARTH

EXTENSION

fireplace

EXTENSION

(shaded)

opening

(shaded)

BAY-40

64 in.

PIER-40

64 in.

(1626 mm)

(1626 mm)

Figure 8.5 Sidewalls/Surrounds

WARNING

Fire Risk

Finish all edges and fronts to clearances and specifications.

Metal fireplace front may be covered with non-combustible material only.

Do NOT overlap combustible materials onto fireplace front.

Install combustible materials up to specified clearances on top front and side edges.

Seal joints between the finished wall and fireplace top and sides using only a 300° F minimum sealant.