Heat & Glo LifeStyle BAY-40 Installation of Fireplace, A. Install the Outside Air Kit, Fire Risk

Models: BAY-40

1 52
Download 52 pages 14.25 Kb
Page 13
Image 13
Installation of Fireplace

4

Installation of Fireplace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

WARNING

 

 

 

 

Fire Risk

 

Sharp Edges

 

 

 

 

 

Asphyxiation Risk

 

• Wear protective gloves and safety glasses

 

 

 

 

 

Do not draw outside combustion air from:

 

during installation.

 

 

 

 

 

• Wall, floor or ceiling cavity.

 

 

 

 

 

 

 

 

• Enclosed space such as an attic or

 

 

 

 

garage.

 

 

 

 

 

 

 

 

• Close proximity to exhaust vents or

 

 

 

 

chimneys.

A. Install the Outside Air Kit

 

Fumes or odor may result.

This fireplace will operate correctly only if adequate ventila-

 

 

 

tion is provided to allow proper draft to the fireplace system.

 

CAUTION

See Section 2.

 

The outside air kit is supplied with this fireplace. Using an

Risk of Smoke Spillage

outside air kit is highly recommended to minimize the effects

Outside air inlet must be located to prevent blockage

of negative pressure within the structure. We recommend

from:

 

 

you utilize the shortest duct run to optimize the performance

Leaves

of the outside air kit. Cold air flow can be minimized by put-

Snow/ice

ting a small dip in the duct creating a cold air trap. This trap

Other debris

can also help prevent heat build-up and exhausting out the

Blockage may cause combustion air starvation.

intake due to the stack effect. The outside air kit inlet should

 

 

 

be positioned in a manner that will not allow snow, leaves,

 

 

 

etc. to block the inlet. In some installations the air duct

The outside air kit is installed on the right side (PIER-40)

may need to be run vertically. In such an installation, a 3 ft

or open end (BAY-40) of the fireplace. See Figure 4.4 for

(.914 m) height difference must be maintained from the top

handle location/operation.

of the uppermost chimney section to the outside combustion

Remove the cover plate from the side (PIER-40) or bottom

air inlet. See Figure 4.2.

(BAY-40) of the fireplace assembly where the air kit is to be

See Figure 4.3 for proper placement of outside air inlet.

installed.

 

Flexible Duct

 

 

 

(not supplied)

 

 

 

 

Outside Air

 

Outside Air

 

Plate

 

 

Assembly

 

Shield

2 Wire Ties

 

 

 

Figure 4.1 Outside Air Installation

 

 

Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07