4 | Installation of Fireplace |
|
|
| ||
|
|
|
| |||
|
|
|
|
|
| |
| CAUTION |
|
| WARNING | ||
|
|
|
| Fire Risk | ||
| Sharp Edges |
|
| |||
|
|
| Asphyxiation Risk | |||
| • Wear protective gloves and safety glasses |
|
| |||
|
|
| Do not draw outside combustion air from: | |||
| during installation. |
|
| |||
|
|
| • Wall, floor or ceiling cavity. | |||
|
|
|
| |||
|
|
|
| • Enclosed space such as an attic or | ||
|
|
|
| garage. | ||
|
|
|
| |||
|
|
|
| • Close proximity to exhaust vents or | ||
|
|
|
| chimneys. | ||
A. Install the Outside Air Kit |
| Fumes or odor may result. | ||||
This fireplace will operate correctly only if adequate ventila- |
|
|
| |||
tion is provided to allow proper draft to the fireplace system. |
| CAUTION | ||||
See Section 2. |
| |||||
The outside air kit is supplied with this fireplace. Using an | Risk of Smoke Spillage | |||||
outside air kit is highly recommended to minimize the effects | Outside air inlet must be located to prevent blockage | |||||
of negative pressure within the structure. We recommend | from: |
|
| |||
you utilize the shortest duct run to optimize the performance | • | Leaves | ||||
of the outside air kit. Cold air flow can be minimized by put- | • | Snow/ice | ||||
ting a small dip in the duct creating a cold air trap. This trap | • | Other debris | ||||
can also help prevent heat | Blockage may cause combustion air starvation. | |||||
intake due to the stack effect. The outside air kit inlet should | ||||||
|
|
| ||||
be positioned in a manner that will not allow snow, leaves, |
|
|
| |||
etc. to block the inlet. In some installations the air duct | The outside air kit is installed on the right side | |||||
may need to be run vertically. In such an installation, a 3 ft | or open end | |||||
(.914 m) height difference must be maintained from the top | handle location/operation. | |||||
of the uppermost chimney section to the outside combustion | Remove the cover plate from the side | |||||
air inlet. See Figure 4.2. | ||||||
See Figure 4.3 for proper placement of outside air inlet. | ||||||
installed. |
| Flexible Duct |
|
|
| (not supplied) |
|
|
|
| Outside Air |
|
Outside Air |
| Plate |
|
| Assembly |
| |
Shield | 2 Wire Ties |
| |
|
| ||
Figure 4.1 Outside Air Installation |
|
| |
Heat & Glo • | 13 |