Heat & Glo LifeStyle BAY-40 F. Double-check the Chimney Assembly, G. Secure the Chimney, Straps

Models: BAY-40

1 52
Download 52 pages 14.25 Kb
Page 21
Image 21
F. Double-check the Chimney Assembly

F. Double-check the Chimney Assembly

Continue assembling the chimney sections up through the ceiling firestops as needed. While doing so, be aware of the height and unsupported chimney length limitations given un- der Section 5.A. Chimney Requirements.

Check each section by pulling up slightly from the top to en- sure proper engagement before installing the succeeding sections. If they have been connected correctly, they will not disengage when tested.

G. Secure the Chimney

Straps

G. Secure the Chimney Ceiling Firestop

Joint

Band

When offsets and returns are joined to straight pipe sections, they must be locked into position with the screws provided* (outer only), using the predrilled holes. To prevent gravity from pulling the chimney sections apart, the returns and the chimney stabilizers have hanger straps for securing these parts to joists or rafters. See Figure 5.9.

*or equivalent #6 or #8 sheet metal screw no longer than 3/4 in. (19 mm).

Straps WARNING

Fire Risk

Secure offsets with screws (not to exceed 3/4 in./19 mm in length).

Secure returns with strapping.

Straight chimney sections may be secured with screws (not to exceed 3/4 in./19 mm in length) at the joints.

Keep chimney sections from separating or twisting.

Optional(Optional)

Additional

Support

Figure 5.9 Secure the Chimney

Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07

21

Page 21
Image 21
Heat & Glo LifeStyle BAY-40 owner manual F. Double-check the Chimney Assembly, G. Secure the Chimney, Straps, Fire Risk