For installations utilizing an ST475 Square Termination Cap the last chimney section must not be more than 4-1/2 in. (114 mm) below the chase top. See Figure 6.7.

 

 

 

 

 

 

Flashing Collar

Cap Standoff

 

 

 

 

2 in. (51 mm) min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-1/2 in.

1-1/2 in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(38 mm) min.

 

 

 

 

 

(114 mm)

overlap

Top of Pipe

 

 

 

 

 

 

max.

Figure 6.7 Installing an ST475 Square Termination Cap

For chase installations you can use a TR444 Round Termination Cap, a TR442 Round Telescoping Termination Cap, or an ST475 Square Termination Cap.

Install termination caps following instructions provided with them.

Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06

23

Page 23
Image 23
Heat & Glo LifeStyle EXCLAIM-36T-C, EXCLAIM-36H-C owner manual Installing an ST475 Square Termination Cap