4

Installation of Fireplace

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

WARNING

 

 

 

 

Fire Risk

 

 

Sharp Edges

 

 

 

 

Asphyxiation Risk

 

 

• Wear protective gloves and safety glasses

 

 

 

 

Do not draw outside combustion air from:

 

 

during installation.

 

 

 

 

• Wall, floor or ceiling cavity.

 

 

 

 

 

 

 

 

• Enclosed space such as an attic or

 

 

 

 

garage.

 

A. Install the Outside Air Kit

 

 

• Close proximity to exhaust vents or

 

This fireplace will operate correctly only if adequate ventila-

 

chimneys.

 

tion is provided to allow proper draft to the fireplace system.

 

Fumes or odor may result.

 

See Section 2.

 

 

 

 

 

 

The outside air kit is supplied with this fireplace and its use is highly recommended to minimize the effects of negative pressure within the structure. We recommend you utilize the shortest duct run to optimize the performance of the outside air kit. Cold air flow can be minimized by putting a small dip in the duct creating a cold air trap. This trap can also help prevent heat build-up and exhausting out the intake due to the stack effect. The outside air kit inlet should be positioned in a manner that will not allow snow, leaves, etc. to block the inlet. In some installations the air duct may need to be run vertically. In such an installation, a 3 ft (.914 m) height difference must be maintained from the top of the upper- most chimney section to the outside combustion air inlet. See Figure 4.2.

See Figure 4.3 for proper placement of outside air inlet.

The outside air kit is installed on the left hand side of the fireplace. See Figure 4.4 for handle location/operation.

CAUTION

Risk of Smoke Spillage

Outside air inlet must be located to prevent blockage from:

Leaves

Snow/ice

Other debris

Blockage may cause combustion air starvation.

 

Flexible Duct

 

 

 

(not supplied)

 

 

Outside Air

 

 

 

Shield

2 Wire Ties

Inlet Ring

 

Figure 4.1 Outside Air Installation

 

 

Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06